1).Input A Polarity
Parameter Code number: 01
Parameter Range: [0, 1], the default value is 0
0 — The actuator will move out when edge detector A is blocked, or the Eagle Eye I sensor’s sight point is to the left of
the line or edge it is following.
1 — The actuator will move out when edge detector A is unblocked, or the Eagle Eye I sensor’s sight point is to the right
of the line or edge it is following.
2).Input B Polarity
Parameter Code number: 02
Parameter Range: [0, 1], the default value is 0
0 — The actuator will move out when edge detector B is blocked, or the digital line guide’s sight point is to the left of the
line or edge it is following
1 — The actuator will move out when edge detector B is unblocked, or the digital line guide’s sight point is to the right of
the line or edge it is following
3).Maximum Deadband
Parameter Code number: 03
Parameter Range: [0-99 ],the default value is 28
The Maximum deadband is a zone around the sensor guide point where the motor drive is turned off. The higher the
Maximum Deadband value is set, the farther the web edge or line must move away from the guide point before the motor
drive is turned on. This parameter is typically used to compensate for edge curl and web flutter. The Maximum Deadband
value must be higher than the Minmium Deadband value.
4).Minimum Deadband
Parameter code number: 04
Parameter range: [ 0-99 ] The default value is 14
The minimum deadband is a zone around the sensor guide point that the web edge or line position enters this zone, it
must then move outside of the Maximum deadband zone before the motor drive is turned on. The minimum Deadband
value must be lower than the Maximum Deadband value.
5).Auto-Mode Speed Limit
Parameter code number: 05
Parameter range: [20-60], the default value is 26
This parameter limits the max speed of the actuator in Automatic mode, the higher this value is, the faster the actuator
can move.
6).Manual-Mode Speed
Parameter code number: 06
Parameter range: [15-60], the default value is 30
This parameter determines how fast the actuator will move in Manual and Servo-Center mode . The
higher this value is, the faster the actuator will move.
Содержание AWG5000
Страница 1: ......
Страница 2: ......
Страница 28: ...ጝሁႠీ ਝൽጆॆ 26 Appendix I Application drawing for control enclosure installation ...
Страница 29: ...ጝሁႠీ ਝൽጆॆ 27 Appendix II Edge detector application drawing ...
Страница 30: ...ጝሁႠీ ਝൽጆॆ 28 Appendix III Installation drawing for EAGLE EYE I photoelectric sensor ...
Страница 31: ......
Страница 32: ......