The LCD Display 

 

Display 

Function 

Display 

Function 

Input Information 

Output Information 

 

It indicates input 

voltage/frequency value, which 

are displayed alternately. 

 

It indicates output 

voltage/frequency value, which 

are displayed alternately. 

 

It indicates the input is 

connected with mains, and the 

input power is supplied from 

the mains. 

 

 

It indicates the Output plug. 

 

It indicates the Number of the 

input supplied from the mains. 

 

It indicates the Number of the 

output connected with load. 

Battery Information 

Load Information 

 

It indicates the battery capacity. 

Every  grid  represents  the 

capacity of 20%. 

 

 

It indicates the load level. Every 

grid  represents  the  level  of 

20%. 

Mode/Fault/Warning Information 

Else 

 

 

It indicates the UPS is in setting 

mode. 

 

 

It Indicates the operating mode 

or  Fault  kind  or  Warning  kind, 

several  warning  kinds  at  the 

same  time  could  be  displayed 

alternately. 

 

 

It  indicates  the  UPS  is  in  Fault 

mode or has some warnings. 

 

19 

5. Connection and Operation

 

 
 
 
 
 
 
 

5.1 Inspection:   

Inspect the packaging carton and its contents for damage. Please inform the 
transport agency immediately should you find signs of damage. 

Please keep the packaging in a safe place for future use. 

Note:  Please  ensure  that  the  incoming  feeder  is  isolated  and  secured  to 
prevent it from being switched back on again. 

5.2 Connection: 

(1) UPS Input Connection 

If the UPS is connected via the power cord, please use a proper socket with 
protection  against  electric  current,  the  user  can  refer  to  below  table.  If  the 
UPS  is  connected  via  wires,  it  is  recommended  to  select  the  2.5mm

2

  wire, 

and the “GND” terminal should be grounded first. 

The  UPS  System  has  no  input  breaker  on  the  standard  cabinet.  When 
installing  the  UPS,  the  user  needs  to  connect  the  external  breakers  and 
protective components in the input terminals. It is recommended to select the 
NFB(Non-Fuse  Breaker)  instead  of  the  traditional  combination  kit  including 
breaker and fuse. 

When selecting the NFB, the user can refer to below table. 

UPS INPUT NFB & Power Cord & Socket 

Model No. 

VOLTAGE 

CURRENT 

1K & 1K-KS 

300Vac 

10A 

2K & 1K-KS 

300Vac 

16A 

3K & 1K-KS 

300Vac 

20A 

 

The system may be installed and wired only by qualified electricians 
in accordance with applicable safety regulations! 

When  installing  the  electrical  wiring,  please  note  the  nominal 
amperage of your incoming feeder. 

Содержание AP160N Series 1000VA

Страница 1: ...iption 17 5 Connection and Operation 19 5 1 Inspection 19 5 2 Connection 19 5 3 Battery charge 21 5 4 Turn on the UPS 21 5 5 Test function 21 5 6 Turn off the UPS 22 5 7 Audible alarm mute function 22...

Страница 2: ...ssure to connect with the earth reliably Assure external battery source must be earthed Connect the UPS only to an earthed shockproof socket outlet The building wiring socket outlet shockproof socket...

Страница 3: ...the end of the tower 2 Place down the UPS into two stands carefully 3 Pull out the LCD box and rotate it in a clockwise direction to 90 degree and then push it back in the front panel 5 l Rack mount...

Страница 4: ...battery terminal A from UPS to EBM terminal B shown as below Users need to remove the small gate C on side of the front panel to allow the outlet wire of the EBM to pass through the gate and then reas...

Страница 5: ...the gate and then reassemble front panel B C A D E 9 Note Three or more EBMs can be connected to the UPS in the same way as shown above Note After connect the EBMs please do not forget to set the num...

Страница 6: ...alified maintenance personnel 1 3 1 UPS and Battery Care For the best preventive maintenance keep the area around the UPS clean and dust free If the atmosphere is very dusty clean the outside of the s...

Страница 7: ...ake on off the load To test batteries 1 Connect the UPS to utility power for at least 48 hours to charge the batteries 2 Press and hold the I button 1 second to start the battery test on line mode or...

Страница 8: ...D IEC EN 61000 4 2 Level 3 RS IEC EN 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 SURGE IEC EN 61000 4 5 Level 4 CS IEC EN 61000 4 6 Level 3 MS IEC EN 61000 4 8 Level 3 Voltage Dips IEC EN 61000 4 1...

Страница 9: ...KS Extended backup time 17 4 Panel Description The Display Panel Switch Function ON Button Turn on UPS system By pressing the ON Button I the UPS system is turned on Deactivate acoustic alarm By press...

Страница 10: ...orm the transport agency immediately should you find signs of damage Please keep the packaging in a safe place for future use Note Please ensure that the incoming feeder is isolated and secured to pre...

Страница 11: ...ed 5 4 Turn on the UPS 1 With utility power connecting Press I button continuously for more than 1 second to turn on the UPS the UPS will get into the inverter mode the LCD screen will indicate the st...

Страница 12: ...will cause abnormality or permanent damage 2 One hard wiring type battery terminal on the rear panel is used for connecting the battery pack 3 The battery connection procedure is very important Any i...

Страница 13: ...nominal power capacity 25 Note Please follow the following steps to connect the generator l Activate the generator and wait until the operation is stable before supplying power of the generator to th...

Страница 14: ...hile the utility power is in normal range so the high efficiency could be gained in the ECO mode Once the mains is loss or abnormal the UPS would transfer to battery mode and the load is supplied cont...

Страница 15: ...for more than 10 seconds the setting mode exit automatically The output frequency string OPF Bypass status string bYPA operating mode string MOdE Battery string bSTR Load segment string LS1 and LS2 wo...

Страница 16: ...battery voltage is normal and the mains is normal charge automatically again Battery low Battery voltage is low When audible alarm sounding every second battery is almost empty 31 Charge fail The cha...

Страница 17: ...d start the UPS If it needs to replace the batteries while the UPS is running make sure the UPS would not shut down during the replacement If there is a battery breaker then turn it off first Disconne...

Страница 18: ...a computer connect one end of the serial communication cable that comes with the UPS to the RS 232 port on the UPS Connect the other end of the serial cable to the RS 232 port on a computer The cable...

Страница 19: ...er WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems...

Страница 20: ...1 AC Output 2 EPO Dry input Communication Port 3 USB Port 4 AC Input 5 Dry out 6 SNMP slot 7 RS232 8 Modem Network Surge Protection 9 Earth Line connection 39 1 1 3K Standard model rear panel 3K KS mo...

Отзывы: