background image

POWERWARE

®

5115A USB

User’s Guide

500-1400 VA

www.powerware.com.au

Summary of Contents for Powerware 5115A USB

Page 1: ...POWERWARE 5115A USB User s Guide 500 1400 VA www powerware com au...

Page 2: ...s reserved Powerware is a registered trademark and Advanced Battery Management ABM is a trademark of Powerware Corporation Where the brand name Powerware is used the term refers to Eaton s Powerware D...

Page 3: ...POWERWARE 5115A USB 500 1400 VA User s Guide www powerware com au...

Page 4: ...UAL Refer to your operator s manual for additional information such as important operating and maintenance instructions SAFETY EARTHING TERMINAL Indicates the primary safety ground LOAD ON OFF Press t...

Page 5: ...PS On 9 Starting the UPS on Battery 9 Turning the UPS Off 9 Standby Mode 9 UPS Front Panel 10 Initiating the Self Test 10 4 Additional UPS Features 11 Communication Port 11 USB Port 12 Network Transie...

Page 6: ...7 Troubleshooting 25 Audible Alarms and UPS Conditions 25 Silencing an Audible Alarm 25 Service and Support 29 8 Warranty Information 31...

Page 7: ...n occur when you least expect it and power quality can be erratic Power problems have the potential to corrupt critical data destroy unsaved work sessions and damage hardware causing hours of lost pro...

Page 8: ...Advanced Battery Management ABM doubles battery service life optimises recharge time and provides advanced warning before the end of battery life Buck and Boost voltage regulation ensures consistent v...

Page 9: ...operating the equipment and save this manual for future reference IMPORTANT SAFETY INSTRUCTIONS WARNING This UPS contains its own energy source batteries The output receptacles may carry live voltage...

Page 10: ...tion only See UPS Rear Panels on page 6 for the rear panel of each model 1 If you are installing power management software connect your computer to the USB port of UPS communication port using the sup...

Page 11: ...r is available from the UPS output receptacles The UPS conducts a self test and enters Normal mode If the alarm beeps or a UPS alarm indicator stays on see Table 8 on page 26 The installation is compl...

Page 12: ...of the Powerware 5115 models Figure 3 500VA Rear Panel Figure 4 750VA Rear Panel USB Port Network Transient Protector 3 x 10A Australian Output Receptacles IEC 320 10A Input Connector Communication P...

Page 13: ...l Figure 6 1400VA Rear Panel 3 x 10A Australian Output Receptacles USB Port Network Transient Protector IEC 320 10A Input Connector Communication Port Fan USB Port Network Transient Protector 3 x 10A...

Page 14: ...8 Powerware 5115A USB User s Guide www powerware com au...

Page 15: ...n the UPS without using utility power press and hold the button for two seconds When the UPS starts on battery it does not conduct a self test to conserve battery power Tu r n i n g t h e U P S O f f...

Page 16: ...beeps or any alarm indicators are on see Table 8 on page 26 to identify and correct the problem I n i t i a t i n g t h e S e l f Te s t Press and hold the button for three seconds to initiate the sel...

Page 17: ...on between the UPS and a computer connect your computer to the UPS communication port using the supplied communication cable When the communication cable is installed power management software can exc...

Page 18: ...ng 2 RxD Transmit to external device Out 3 TxD Receive from external device In 4 DTR PnP Plug and Play from external device tied to Pin 6 In 5 GND Signal common tied to chassis 6 DSR To external devic...

Page 19: ...or shown in Figure 10 is located on the rear panel and has jacks labelled IN and OUT This feature accommodates a single RJ 45 10BaseT network connector Connect the input connector of the equipment you...

Page 20: ...14 Powerware 5115A USB User s Guide www powerware com au...

Page 21: ...re of 25o C Storing the UPS and Batteries If you store the UPS for a long period recharge the battery every 6 months by plugging the UPS into a power outlet The batteries charge to 90 capacity in appr...

Page 22: ...sk of electrical shock or burn from high short circuit current The following precautions should be observed 1 Remove watches rings or other metal objects 2 Use tools with insulated handles 3 Do not la...

Page 23: ...teps to replace the batteries 1 Pull the top left corner forward and remove the front panel 2 Slide up and remove the metal battery cover 3 500VA units Disconnect the red battery cable and then discon...

Page 24: ...USB User s Guide www powerware com au 4 750 1400VA units Disconnect the red battery cable and then pull the battery out onto a flat stable surface Disconnect the black battery cable to the UPS as sho...

Page 25: ...ed by the indicator If there is a problem with the battery the alarm beeps the indicator illuminates and the indicator flashes Check the battery connections and be sure the battery is fully charged Ca...

Page 26: ...20 Powerware 5115A USB User s Guide www powerware com au...

Page 27: ...PW5115 1000A USB PW5115 1400A USB UPS Dimensions 500VA 150 x 193 x 270 mm W x H x D 750 1000VA 150 x 193 x335 mm 1400VA 150 x 193 x 390 mm UPS Mass 500VA 7 8 kg 750VA 12 4 kg 1000VA 12 6 kg 1400VA 16...

Page 28: ...ine wave Overcurrent Protection Inverter saturation current limited Output Receptacles 3 x 10A Australian Table 5 Environmental and Safety Operating Temperature Up to 1 500 metres 0o C to 40o C Over 1...

Page 29: ...arging Advanced charging for faster recovery less than 3 hours to 90 usable capacity at nominal line and no supplementary power supply load Monitoring Advanced monitoring for earlier failure detection...

Page 30: ...24 Powerware 5115A USB User s Guide www powerware com au...

Page 31: ...e returning the unit for any reason This section explains UPS alarms and conditions How to silence an alarm Service and Support A u d i b l e A l a r m s a n d U P S C o n d i t i o n s The UPS has an...

Page 32: ...to expected backup time discharged because of charge the battery Press the button if the alarm long term storage beeps see Replacing the Batteries on page 16 to frequent power outages replace the batt...

Page 33: ...UPS 1 beep per The UPS is on battery and Shutdown is imminent 30 seconds Save your work second the power requirements and turn off your equipment Turn off the UPS exceed UPS capacity Remove some of t...

Page 34: ...the button for 3 seconds Then check the indicator If the still flashes see UPS Maintenance on page 15 to replace the battery Continuous The output wave is Shutdown is imminent Save your work and turn...

Page 35: ...s we will give you a Return Authorisation RA number When you return a Powerware 5115 to the factory for any reason please use the original packing material in which your unit was shipped to you You ma...

Page 36: ...30 Powerware 5115A USB User s Guide www powerware com au...

Page 37: ...r other service locations as nominated by EPQ provided the unit has been returned by the user packed adequately to prevent shipping damage and approval has been obtained from EPQ before shipment All c...

Page 38: ...from despatch date as per invoice A copy of this warranty statement is available on request Batteries provided as spare parts or replacements have a one year warranty Other optional warranty terms for...

Page 39: ...ware further warrants its UPS will have a service life of ten years from the date of shipment from Powerware s factory when used in accordance with the storage handling installation operation and main...

Page 40: ...ware will not accept any product for return credit or exchange unless expressly authorised by Powerware in writing and delivered to F O B Powerware s factory Nor will Powerware be responsible for any...

Page 41: ...Eaton Power Quality Pty Ltd 13 Healey Road DANDENONG VIC 3175 AUSTRALIA A F F I X P O S TA G E S TA M P...

Page 42: ...product developments and 1 Where did you purchase this Powerware UPS from Retail Store Computer Store Powerware Distributor Direct from Powerware Electrical Wholesaler Mail Order Catalogue Internet O...

Page 43: ...e com au Customer Service Offices Adelaide Brisbane PO Box 481 Marlestone Business Centre Unit 4 11 Donkin Street SA 5033 West End QLD 4101 Phone 08 8347 3622 Phone 07 3891 1211 Fax 08 8445 6328 Fax 0...

Page 44: ...ems to 1MVA Plug in Power Conditioners to 3kVA Hardwired Single Phase Power Conditioners to 22 5kVA Constant Voltage Transformers to 7 5kVA AC DC switching and linear Power Supplies CVDC Constant Volt...