10.4 Dimensions and weights 

Model 

1K 

1K-KS 

2K 

2K-KS 

3K 

3K-KS 

Net weight (kg) 

16,2 

8,4 

19,7 

9,3 

28,6 

13,2 

UPS 

Cabinet  Dimension (mm) 

(W x H x D) 

Dimension (mm) 

(W x H x D) 

438x86,5x436 

438x86,5x608 

Net weight (kg) 

22,2 

27,5 

40,5 

Battery

Cabinet 

Type 

36V 

48V 

72V 

 

11. Communication Port

 

11.1 RS-232 and USB communication ports 

To  establish  communication  between  the  UPS  and  a  computer,  connect  a 
computer  to  one  of  the  UPS  communication  ports  by  using  an  applicable 
communication cable.   

 
 
 
 
 

 
 
 
 
 

  NOTE: 

Only one of the communication ports can be active at one time. The USB port has 
priority over the RS-232 port. 
When a communication cable is installed, the power management software can 
exchange data with the UPS. The software polls the UPS for detailed information 

on  the  status  of  the  power  environment.  If  a  power  emergency  occurs,  the 
software initiates the saving of all data and an orderly shutdown of the equipment 

 

 

35 

11.2 RS-232 port 

The  RS-232  port  is  available  for  UPS  monitoring,  control,  and  firmware 
updates.  To  establish  communication  between  the  UPS  and  a  computer, 
connect one end of the serial communication cable that comes with the UPS to 
the RS-232 port on the UPS. Connect the other end of the serial cable to the 
RS-232 port on a computer. 
The  cable  pins  for  the  RS-232  communication  port  are  identified  in  the 
following illustration.   
RS-232 communication port pin assignments 

 

Pin  Signal name 

Function 

Direction 

from 

the UPS 

 

Unused 

Not applicable 

Tx 

Transmit to external device 

Out 

Rx 

Receive from external device  In 

 

Unused 

Not applicable 

GND 

Signal common   
(tied to chassis) 

Not applicable 

 

Unused 

Not applicable 

 

Unused 

Not applicable 

 

Unused 

Not applicable 

 

Unused 

Not applicable 

 

11.3 USB port 

The  UPS  can  communicate  with  a  USB-compliant  computer  by  using 
HID-compatible  power  management  software.  To  establish  communication 
between the UPS and a computer, connect the USB cable that comes with the 
UPS to the USB port on the UPS. Connect the other end of the USB cable to 
the USB port on a computer. 

11.4 Installing a Serial Network Management Card (optional) 

Each UPS has one available communication bay, which supports the optional 
Serial  Network  Management  Card.  After  you  install  a  Serial  Network 
Management Card, you can connect an environmental monitoring probe to the 
UPS. 

 

Содержание AP160N Series 1000VA

Страница 1: ...iption 17 5 Connection and Operation 19 5 1 Inspection 19 5 2 Connection 19 5 3 Battery charge 21 5 4 Turn on the UPS 21 5 5 Test function 21 5 6 Turn off the UPS 22 5 7 Audible alarm mute function 22...

Страница 2: ...ssure to connect with the earth reliably Assure external battery source must be earthed Connect the UPS only to an earthed shockproof socket outlet The building wiring socket outlet shockproof socket...

Страница 3: ...the end of the tower 2 Place down the UPS into two stands carefully 3 Pull out the LCD box and rotate it in a clockwise direction to 90 degree and then push it back in the front panel 5 l Rack mount...

Страница 4: ...battery terminal A from UPS to EBM terminal B shown as below Users need to remove the small gate C on side of the front panel to allow the outlet wire of the EBM to pass through the gate and then reas...

Страница 5: ...the gate and then reassemble front panel B C A D E 9 Note Three or more EBMs can be connected to the UPS in the same way as shown above Note After connect the EBMs please do not forget to set the num...

Страница 6: ...alified maintenance personnel 1 3 1 UPS and Battery Care For the best preventive maintenance keep the area around the UPS clean and dust free If the atmosphere is very dusty clean the outside of the s...

Страница 7: ...ake on off the load To test batteries 1 Connect the UPS to utility power for at least 48 hours to charge the batteries 2 Press and hold the I button 1 second to start the battery test on line mode or...

Страница 8: ...D IEC EN 61000 4 2 Level 3 RS IEC EN 61000 4 3 Level 3 EFT IEC EN 61000 4 4 Level 4 SURGE IEC EN 61000 4 5 Level 4 CS IEC EN 61000 4 6 Level 3 MS IEC EN 61000 4 8 Level 3 Voltage Dips IEC EN 61000 4 1...

Страница 9: ...KS Extended backup time 17 4 Panel Description The Display Panel Switch Function ON Button Turn on UPS system By pressing the ON Button I the UPS system is turned on Deactivate acoustic alarm By press...

Страница 10: ...orm the transport agency immediately should you find signs of damage Please keep the packaging in a safe place for future use Note Please ensure that the incoming feeder is isolated and secured to pre...

Страница 11: ...ed 5 4 Turn on the UPS 1 With utility power connecting Press I button continuously for more than 1 second to turn on the UPS the UPS will get into the inverter mode the LCD screen will indicate the st...

Страница 12: ...will cause abnormality or permanent damage 2 One hard wiring type battery terminal on the rear panel is used for connecting the battery pack 3 The battery connection procedure is very important Any i...

Страница 13: ...nominal power capacity 25 Note Please follow the following steps to connect the generator l Activate the generator and wait until the operation is stable before supplying power of the generator to th...

Страница 14: ...hile the utility power is in normal range so the high efficiency could be gained in the ECO mode Once the mains is loss or abnormal the UPS would transfer to battery mode and the load is supplied cont...

Страница 15: ...for more than 10 seconds the setting mode exit automatically The output frequency string OPF Bypass status string bYPA operating mode string MOdE Battery string bSTR Load segment string LS1 and LS2 wo...

Страница 16: ...battery voltage is normal and the mains is normal charge automatically again Battery low Battery voltage is low When audible alarm sounding every second battery is almost empty 31 Charge fail The cha...

Страница 17: ...d start the UPS If it needs to replace the batteries while the UPS is running make sure the UPS would not shut down during the replacement If there is a battery breaker then turn it off first Disconne...

Страница 18: ...a computer connect one end of the serial communication cable that comes with the UPS to the RS 232 port on the UPS Connect the other end of the serial cable to the RS 232 port on a computer The cable...

Страница 19: ...er WinPower is a brand new UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems...

Страница 20: ...1 AC Output 2 EPO Dry input Communication Port 3 USB Port 4 AC Input 5 Dry out 6 SNMP slot 7 RS232 8 Modem Network Surge Protection 9 Earth Line connection 39 1 1 3K Standard model rear panel 3K KS mo...

Отзывы: