Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
35/41
5.2 Holding Registers
Holding Registers are readable / writable 16-bit data registers.
The data is arranged that can be changed from the host device such as the power supply setting.
Unless otherwise specified, each set value is retained even after GXE input is shut down.
#
Starting Address
Qty. Function
1
Remote On / Off
0 (0x0000)
1
Register for remote control by communication.
(Volatile)
The power will be remote off at the next input.
This register is not retained after GXE input is shut down.
Remote On / Off
5 (0x0005)
1
Register for remote control by communication.
(Non-Volatile)
Remote On / Off information that was set
before input shutdown is applied at next input.
· Common items of volatile / nonvolatile registers
Remote control of GXE output by writing the reference value
to the register.
T he register setting value
Value
Function
Overview
0 *
Remote Off
Output Off is commanded.
1
Remote On
Output On is commanded.
* Factory setting
It is necessary to change to the setting where communication input
function is enabled with CNT setting register.
Since the remote On / Off register is not referenced depending on
the set value of the CNT setting register,
make appropriate settings according to the system.
2
Remote control Setting
100 (0x0064)
1
Register for setting related to remote control function.
(RC Setting)
Set the remote control (RC) mode and set the Debounce Count
at analog RC.
T he register setting value
Byte
Function
Max.
Min.
Factory Setting
LSB
RC Mode
4
0
0
MSB
Debounce Count
100
0
10
Holding Register