Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
20/41
4.1.1 GXE Output
When the Remote Control (RC) mode is other than "0" (AnalogRC) *, it is possible to control the output of GXE
by operating the [GXE Output] area during connection status.
* The factory default RC mode is set to "mode 0: AnalogRC" (remote control by communication is disabled).
For details on changing the CNT mode, refer to "· CNT Setting [CNT CFG] Dialog".
T he following two registers (volatile / non-volatile) are prepared for the output control register according to the usage purpose.
T he [Remote On] and [Remote Off] buttons control the output of GXE
according to the control register setting (volatile / non-volatile).
For details, refer to the "Remote On / Off" section of "4.4 Holding register details" in the communication manual.
Button
GXE behavior
Remote On
Issue a remote On query to the "volatile / non-volatile" register displayed in the control register.
Remote Off
Issue a remote Off query to the "volatile / non-volatile" register displayed in the control register.
Control register
Register behavior
Volatile
Register contents are cleared after input shutdown.
(The GXE will be remote Off at the next input applied.)
Non-Volatile
T he current register contents are retained even after input shutdown.
T he control register is set automatically when GXE Access is connected with the GXE or when RC mode register is changed.
Also, it can be manually operated.
Control Register
[Remote On] Button
[Remote Off] Button
Click the control register window and select the target register.
4.1.2 T ab screen
Registers are displayed in the tab display area, except for "GXE output control" and "measurement information".
Holding Reg1-3
: Readable / writable data such as setting registers are arranged.
Input Reg
: Read-only data other than measurement information is arranged.