Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
24/41
・
RC CFG Dialog
In the dialog window, information on register data is displayed for each individual item.
By clicking on the RC Mode field, the choices are displayed.
Item
Overview
RC Mode
Click the display area and select the RC mode.
(T he factory default RC mode is set to "mode 0: Analog RC")
0 : Analog RC
Enable input from the CNT terminal of CN84.
(Remote control by communication is invalid)
1 : Digital RC (Volatile)
Enable remote control by communication. (Analog RC is invalid)
2 : Digital RC (Non-Volatile)
Enable remote control by communication. (Analog RC is invalid)
3 : Mixed RC (Volatile)
T he logical AND of the analog RC and
the digital RC (Volatile) is used as the remote control signal.
4 : Mixed RC (Non-Volatile)
T he logical AND of the analog RC and
the digital RC (Non-Volatile) is used as the remote control signal.
In Mixed RC mode, the GXE output only when both analog RC and digital RC are remote ON.
Debounce Count
Sets the filter time for removing the debounce of the analog CNT pin.
Enter a value between 0 and 100 [ms] directly in the edit area. (Factory setting 10 [ms])
T he following table shows the relationship between remote control input combinations and power output in each RC mode.
Analog RC
Digital RC
Volatile
Non-Volatile
Enable
invalid
OFF
x
x
OFF
ON
x
x
ON
Disable
valid
x
OFF
x
OFF
(Volatile)
x
ON
x
ON
Disable
valid
x
x
OFF
OFF
(Non-Volatile)
x
x
ON
ON
Enable
valid
OFF
x
(Volatile)
ON
x
OFF
x
ON
x
ON
Enable
valid
x
OFF
(Non-Volatile)
x
ON
x
OFF
x
ON
ON
x : It is not referred.
By clicking the [OK] button, the data in the display area is updated based on the setting on the dialog.
Please close the dialog and then click the [Write] button.
Otherwise GXE settings will not be updated, so please be careful.
Output
Value
Digital RC
OFF
ON
1
2
3
OFF
OFF
ON
0
(Factory setting)
Control mode
Analog
RC
4
OFF