Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
21/41
4.1.3 Meters
T he monitor function of GXE is allocated as MODBUS register.
Polling checkbox
[Detail] button
[Erase Hist.] Button
Item
Overview
Output Voltage
Register data of measured value of output voltage (b S and - S terminals)
and converted voltage value are displayed.
Output Current
Register data of measured output current value and converted current value are displayed.
Temperature
T he alarm information of the protection operation that occurred is displayed.
You can change the radix by clicking the radix* part in the display area.
When you click the [Bits] button, detailed dialog of alarm history is displayed.
For the detail dialog of alarm history, please see the next page.
Click the button to erase the contents of the [Alarm history] register.
If the protection condition continues even after erasing, the alarm history is set again.
Alarm history is deleted even when GXE output starts other than automatic restoration.
Operation Time
T he cumulative operating time of the GXE is displayed. (not including Remote off time)
E-cap L0 Remain
T he predicted lifetime of the electrolytic capacitor inside the
power supply (standard installation) is displayed as L0 parameter.
Pollong
Select whether to enable automatic update of measurement information.
When "Polling" is checked, measurement information is automatically updated.
Please note that when you uncheck it, the operation of the Multi Monitor tab
in Graphical screen mode also stops.
* About display of radix
Radix part
Click [Radix part] and select the display radix.
Item
Overview
Decimal
It is expressed in decimal.
"d" is displayed in the display area.
Hex
It is expressed in hexadecimal.
"x" is displayed in the display area.
Octal
It is expressed in octal number.
"o" is displayed in the display area.
Binary
It is expressed in binary notation.
"b" is displayed in the display area.
SI Notation
It is expressed by an index.
"p" is displayed in the display area.
Alarm History
Erase Hist.
T he measured value of GXE internal temperature is displayed.
(Because GXE is convection cooling, the value is affected by the installation state of GXE)