Communication GUI Guide
GXE600 Series
TDK-Lambda
<Page>
13/41
3.4 PS Configuration Tab
T his is a setting tab for controlling GXE with GXEAccess.
T he changed settings are retained even after the power input is shut down.
1) Remote control setting
2) CVCC target setting
3) Communication settings
6) "Factory Reset" button 5) "Automatic Settings" button
4) ON / OFF data holding setting
Item
Overview
1
Remote control setting
T his is the remote control setting area of GXE.
It is necessary to set to "Digital" for remoto control by GXE Access.
T he factory setting is "Analog".
Analog
:
Control ON / OFF of GXE by switching electrical contacts.
Digital
:
Control ON / OFF of GXE with communication signal.
Analog AND Digital
:
This mode turns on GXE when both electrical contacts and
communication signals are turned ON.
2
CVCC target setting
T his is the area for setting the CV / CC target source of GXE.
Unselected target input sources are ignored.
Analog
:
GXE works on the reference of output voltage variable volume
and the external voltage to the PV or CC terminal.
Digital
:
GXE works on the reference by communication CV/CC target.
3
Communication settings
T his is the area for settings "Unit ID", "BaudRate", "Parity Bit" of GXE.
T he setting is applied to GXE by clicking "APPLY" button.
After setting, GXE Access will be disconnected.
4
ON / OFF data
It is a button which can change the holding characteristic of
holding setting
the communication remote control ON / OFF signal.
If "Analog" is selected in the remote control setting, it will be grayed out.
・
Volatile Mode
When the AC input of GXE is cut off and restarted,
the output of GXE will start from OFF each time.
・
Non Volatile Mode
When the AC input of GXE is cut off and restarted,
the output of GXE is maintained in the state
before input shutdown.
5
"Automatic Settings"
T his button changes remote control setting and CVCC setting to "Digital".
button
ON / OFF data holding setting is set to "Volatile Mode".
6
"Factory Reset" button
T his button changes the remote control setting and CVCC setting to "Analog".