3-4
TROUBLESHOOTING
Models C712/C713
Troubleshooting
3
17.Drive shaft is stuck in the
gear box coupling.
a. Corners of the drive shaft, coupling, or both
are rounded.
a. Replace the necessary component(s). Do
not lubricate the end of the drive shaft.
b. Mix and lubricant are collected in the drive
coupling.
b. Brush clean the rear shell bearing area
regularly.
18. Freezing cylinder walls
are scored.
a. Bent beater assembly.
a. Replace beater.
b. Missing or worn front bearing.
b. Install or replace front bearing.
c. Scraper blades incorrectly installed.
c. Install scraper blades over the appropriate
securing pin on the beater assembly.
19. Product is “popping”
when drawn.
a. Draw rate set too fast.
a. Set the draw rate at 5 oz. to 7-1/2 oz. of
product per 10 seconds.
b. Pump is assembled/lubed incorrectly
(C712).
b. Assemble pump according to instructions in
the Operator's Manual.
c. Freezer has been turned on and off several
times.
c. Place the unit in the OFF position only when
necessary.
20.Freezer shuts off and
produces a fault tone.
a. Fault alert.
a. Check the fault screen in the operator's
menu.
b. Insufficient air space.
b. Allow 3” (76 mm) minimum clearance
around all sides and install the deflector.
21.When Auto is pressed,
freezer goes into Standby.
a. Mix-out condition.
a. Add mix.
22.“Compressor On Too
Long fault message.
a. Inadequate pump operation (C712).
a. Check the pump operation. Assemble the
pump according to instructions in the
Operator Manual.
b. The draw rate is set too fast.
b. Set the draw rate at 5 oz. to 7-1/2 oz. of
product per 10 seconds.
c. Inadequate air flow.
c. Allow a minimum of 3” (76 mm) around all
sides. Install the deflector provided to
prevent recirculation of warm air.
d. Faulty blower baffle.
d. Repair or replace the blower baffle.
e. Inadequate AXV settings.
e. Set AXV at proper setting. (See “Running
Specifications.”)
23. Product Door Off
message is displayed.
a. The door is off or is loose.
a. Install the door and tighten the hand screws.
b. Door switch is faulty.
b. Replace the switch.
c. The door switch is not properly installed.
c. Make sure the door switch is fully inserted.
d. The 24V relay is faulty.
d. Replace the relay.
e. There is low voltage from the 24V
transformer.
e. Check the power supply connections,
shorts, replace transformer.
Problem
Probable Cause
Remedy
Содержание C712
Страница 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Страница 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Страница 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Страница 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Страница 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Страница 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Страница 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...
Страница 91: ...Section 5 5 1 Models C712 C713 Parts List Parts List C71227F000 C71327F000 50HZ 60HZ w High V 50HZ ...
Страница 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...