6-4
WIRING DIAGRAMS
Models C712/C713
Wiring Diagrams
6
Figure 6-3 Diagram 059898-40 (C712)
Model C712
059898-40
09/14
EXTERNAL
GROUND
N
L1
TERMINAL BLOCK
BLK/WHT
INTERFACE BOARD
POWER TRANSFORMER
BLK
ORN
RED
BLU
16V
L2
EMI FILTER
LOAD
1
L
E
N
I
L
L1
L2
240V
WHT
NOT
CONNECTED
WHT
WHT
GRN/YEL
GRN/YEL
BLK
GRN/YEL
BLK/WHT
POWER
SWITCH
3PDT
BLK
ON
OFF
RED
BLU
GRN/YEL
BLU
BRN
GRN
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP
PRP
RED/BLK
ORN/WHT
NO
NC
DRAW
SWITCH
COM
RIBBON CABLE
RED
BLU
RED
BLU
RED
BLU
RIBBON CABLE
WHT
WHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL
WHT
BLK
M
MIX
PUMP
MOTOR
BLK
OVERLOAD
SWITCH
BLU
2
3
4
WHT
RED
START
RELAY
BEATER
MOTOR
STARTER
COIL
WHT
ORN
WHT/ORN
BLK
BLK
BLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
ORN/WHT
ORN
PUR
YEL
GRN/YEL
GRN/YEL
BLK
SV CABLE
SV CABLE
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2
L1
T1
CONDENSER
BLOWER MTR
M
BLK
BLK
RED
WHT
BEATER MOTOR
STARTER
BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
BLK
CLR
FUSE
15A
1
3
J2
J3
GND
+5V
J5
12
3
4
J6
1 2 3 4 5 6
L1
7
L2
J7
1 2 3 4 5 6 7
3
1
5
J8
J9
J12
J11
12
3
4
5
6
7
8
J10
1
234567
89
10
B
A
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
RED
WHT/RED
ON
OFF
J11
J10
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12
8
1
9
5
WHITE
24 VAC
COM
WHT
BLK/RED
BEATER
MOTOR
INTERLOCK
N.O. SWITCH
USER
INTERFACE
BOARD
- 8 LEDS
- LCD SCREEN
- 9 KEYS
- BEEPER
BLACK
BLU
WHT
BLK
BLU
BLU/WHT
BLU/WHT
RED
RED (+5v)
BLK (GRD)
HOPPER
GROUND
BLK
M
L2
L1
T1
T2
COMPRESSOR
CONTACTOR
WHT
#3 #1
240
1
L
N
TERMINAL BLOCK
BLU/WHT
BLU
BRN
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP/WHT
PRP/WHT
GRA/BLK
RED/BLK
NO
NC
BLK
DRAW
SWITCH
COM
RED
BLU
RED
BLU
RED
BLU
WHT
WHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL WHT
BLK
M
MIX
PUMP
MOTOR
BLK
OVERLOAD
SWITCH
BLU
2
3
4
WHT
RED
START
RELAY
BEATER
MOTOR
STARTER
COIL
WHT
ORN
WHT/ORN
BLK
BLK
BLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
ORN/WHT
ORN
PUR
YEL
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLU/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2
L1
T1
BLK
BEATER MOTOR
STARTER
BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
FUSE
15A
2
4
J2
J3
GND
+5V
J5
12
3
J6
1 2 3 4 5 6
L1
7
L2
J7
1 2 3 4 5 6 7
3
1
5
J8
J9
J12
J11
12
3
4
5
6
7
8
J10
12
3
4
5
6
7
8
9
10
B
A
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12
8
1
9
5
BLU
WHT
BLK
BLK
M
L2
L1
T1
T2
COMPRESSOR
CONTACTOR
#3 #1
J18
1
2
J18
1
0
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY
TOUCHING GROUNDED UNIT BEFORE
HANDLING SOLID STATE COMPONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE
CONNECTED TO PIN 1 AT EACH END.
GROUND FRAME SECURELY
BLK
96 95
96 95
WHT
WHT
ON
OFF
SV CABLE
SV CABLE
SV CABLE
SV CABLE
SV CABLE
BLU
BLU
BLU
WHT
BLK
BLK
RED
BLK
BLK
MIX REF. SYSTEM
(DANFOSS TL3G COMPR.)
M
COMP
FAN
0
1
4
1
11 13
START RELAY
START CAP
BRN
WHT
BLK
BRN
BRN
BRN
BRN
BRN
RIGHT SIDE
CONTROL
LEFT SIDE
CONTROL
BLK
BLK
BLK
BLK
BLK
BLK
WHT
WHT
GRN/YEL
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
ORN/WHT
YEL
BLU/WHT
BLU
BLU
BLK
BLU/WHT
BLU/WHT
J2
J1
GRN/YEL
GRN/YEL
GRN/YEL
ELECTRICAL
ENCLOSURE
GRN/YEL
GRN/YEL
GRN/YEL
ELECTRICAL
ENCLOSURE
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
BLU
BRN
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
GRN/YEL
LEFT SYRUP HEATER
WHT/RED
OPTIONAL
WHT
4
RIGHT SYRUP HEATER
RED/BLK
WHT
OPTIONAL
GRN/YEL
BRN
BLU
BRN
BLU
AIR COOLED
CONDENSER
FAN
M
BLK
BLK
WATER COOLED
1
2
3
4
T8
T1
T7
T4
T5
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
1
2
4
6
BLACK
T1
CP
T2
L1
CP
L2
3
5
ORANGE INTERNAL
RED INTERNAL
YELLOW INTERNAL
BLACK INTERNAL
BLUE
T3
L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
T3
L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
BLACK
BLUE
BEATER MOTOR
CONTACTOR
A.O. SMITH BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLUE INTERNAL
BLUE
1
2
5
4
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
C
S
R
LINE
RELAY
RUN
CAP.
START CAP.
COMPRESSOR
TERMINAL
COVER
ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY
TO HOOK UP A COMPRESSOR USING A START AND RUN
CAPACITOR (CSR) WITH A RELAY.
WHITE
BROWN
BLACK
BROWN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHITE(120 VOLTS)
BLACK(230 VOLTS)
BLACK
BLUE
SEE FIG. 1
FIG. 1
L1
L2
WINDING PROTECTOR
(INTERNAL)
MAIN WINDING
START WINDING
START RELAY
(047702-27)
START CAPACITOR
(047703)
COMPRESSOR WIRING
(MODEL TL3G W/HST)
11
10
13
12
14
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
GE/RBC/MARATHON BEATER MOTOR WIRING
NOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2
BLUE
T3
L3
USE T3 AND L3 WHEN CP
CONTACTS ARE NOT AVAILABLE
J12 OR PURPLE INTERNAL
T1 OR BLUE INTERNAL
T8 OR RED INTERNAL
J9 OR BLACK INTERNAL
A
1
4
5
T4 OR YELLOW INTERNAL
2
FIG. 3
FIG. 2
SEE FIG. 3
SEE FIG. 2
SEE FIG. 3
SEE FIG. 2
CLR
BLK
BLK/RED
BLK/RED
BARREL LIQUID
SOLENOID
WHT
GRY/WHT
BARREL LIQUID
SOLENOID
WHT
GRY/WHT
GRN/YEL
GRN/YEL
BLK
CL
CL
EQUIPOTENTIAL
GROUND
A
A
A
A
UVC4
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
JP1
PINS 1 AND 2
JUMPER INSTALLED- BARREL AND HOPPER
TEMPERATURES ARE CHECKED DURING
AUTO/STANDBY. UNIT IS LOCKED OUT IF
EITHER BARREL OR HOPPER IS TOO WARM FOR
A PERIOD OF TIME. LOCKOUT OCCURS WHEN
BARREL OR HOPPER IS ABOVE 45
F (7
C)
FOR MORE THAN ONE HOUR OR ABOVE 41
F
(5
C) FOR MORE THAN FOUR HOURS.
YES
NO JUMPER INSTALLED-NO LOCKOUT DURING
AUTO/STANDBY IF BARREL OR HOPPER IS TOO
WARM FOR A PERIOD OF TIME.
PINS 3 AND 4
RESERVED (DO NOT USE)
NO
JP2
PINS 1 AND 2
DOMESTIC CONFIGURATION-JUMPER INSTALLED.
HOPPER TEMPERATURE NOT DISPLAYED ON
SCREEN/HEAT SYMBOL KEYS ONLY ACTIVE
WHEN A LOCKOUT CONDITION HAS OCCURRED/
STANDBY KEYS DISABLED.
NO
INTERNATIONAL CONFIGURATION-NO JUMPER
INSTALLED. HOPPER TEMPERATURES
DISPLAYED ON SCREEN/MANUAL HEAT CYCLE
START BY SELECTING HEAT SYMBOL/STANDBY
KEYS FUNCTIONAL.
JP3
RESERVED (DO NOT USE)
NO
JP4
RESERVED (DO NOT USE)
NO
JP5
RESERVED (DO NOT USE)
NO
JP6
RESERVED (DO NOT USE)
NO
JP7
JUMPER INSTALLED DISABLES RESET.
NO
RTCK
RESERVED (DO NOT USE)
NO
DBGEN
RESERVED (DO NOT USE)
NO
LEFT INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1
RESERVED (DO NOT USE)
NO
W2
JUMPER INSTALLED-FORCE BRUSH CLEAN STATUS.
NO
W3
JUMPER INSTALLED-ACTIVATES SYRUP HEATERS.
NO*
W4
RESERVED (DO NOT USE)
NO
W5
RESERVED (DO NOT USE)
NO
W6
JUMPER INSTALLED-REDUCED MIX LOW SENSITIVITY.
NO
W7
JUMPER INSTALLED-REDUCED MIX OUT SENSITIVITY.
NO
J10
PINS 7 & 8
JUMPER INSTALLED W/SWITCH-SELF SERVE
APPLICATION ONLY. LOCKS OUT TOUCH
PANEL. NEW SWITCH ACTS AS THE ON/OFF
ABILITY TO ACTIVATE THE TOUCH PANEL.
NO
A
SOFT SERVE
PERSONALITY
BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE
NO
B
SOFT SERVE
PERSONALITY
BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE
YES
RIGHT INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1
RESERVED (DO NOT USE)
NO
W2
JUMPER INSTALLED-ENABLES 59
F HOPPER
TEMPERATURE CHECK.
YES
W3
RESERVED (DO NOT USE)
NO
W4
RESERVED (DO NOT USE)
NO
W5
RESERVED (DO NOT USE)
NO
W6
JUMPER INSTALLED-REDUCED MIX LOW SENSITIVITY.
NO
W7
JUMPER INSTALLED-REDUCED MIX OUT SENSITIVITY.
NO
A
SOFT SERVE
PERSONALITY
BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE
NO
B
SOFT SERVE
PERSONALITY
BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE
YES
A
B
A
B
J13 J1
J13 J1
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
DRAW
SWITCH
C0M
PANEL
JACK
NO
NC
RED
BLK
DRAW
SWITCH
C0M
NO
NC
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
PANEL
JACK
RED
BLK
WHT
BLK/RED
WHT
WHT
SEE FIG. 4
SEE FIG. 4
SYRUP HEATER
THERMOSTA
190 F OPEN
140 F CLOSE
WHT
WHT
WHT
WHT
O.T.
FIG .4
SELF-SERVICE
ENABLE
ENABLE
DISABLE
(OPTIONAL)
BLK
J1
1
2
GRD
+5V
CLR
J2
J7
UNIVERSAL CONTROL PCB A.
J9
J12
J17
J15
J8
5
4
6
2
1
3
J13
J4
J16
CABLE
RED
GRN WHT
BLK
RIBBON CABLE
RIBBON CABLE
J3
* IF THE UNIT HAS THE INTEGRAL SYRUP OPTION-405, THEN THIS
JUMPER SHOULD BE INSTALLED.
JUMPER SETTINGS
CABLE
OPTIONAL REAR
MIX LEVEL LIGHTS
IN
2
1
4
3
6
5
8
7 10
9
OUT
2
1
4
3
6
5
8
7 10
9
J19 1
2
J20
J19 1
2
J20
CABLE
CABLE
CABLE
CABLE
Model C712
059898-40
09/14
© 2014 Taylor Company
EXTERNAL
GROUND
N
L1
TERMINAL BLOCK
BLK/WHT
INTERFACE BOARD
POWER TRANSFORMER
BLK
ORN
RED
BLU
16V
L2
EMI FILTER
LOAD
1
L
E
N
I
L
L1
L2
240V
WHT
NOT
CONNECTED
WHT
WHT
GRN/YEL
GRN/YEL
BLK
GRN/YEL
BLK/WHT
POWER
SWITCH
3PDT
BLK
ON
OFF
RED
BLU
GRN/YEL
BLU
BRN
GRN
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP
PRP
RED/BLK
ORN/WHT
NO
NC
DRAW
SWITCH
COM
RIBBON CABLE
RED
BLU
RED
BLU
RED
BLU
RIBBON CABLE
WHT
WHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL
WHT
BLK
M
MIX
PUMP
MOTOR
BLK
OVERLOAD
SWITCH
BLU
2
3
4
WHT
RED
START
RELAY
BEATER
MOTOR
STARTER
COIL
WHT
ORN
WHT/ORN
BLK
BLK
BLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
ORN/WHT
ORN
PUR
YEL
GRN/YEL
GRN/YEL
BLK
SV CABLE
SV CABLE
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2
L1
T1
CONDENSER
BLOWER MTR
M
BLK
BLK
RED
WHT
BEATER MOTOR
STARTER
BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
BLK
CLR
FUSE
15A
1
3
J2
J3
GND
+5V
J5
12
3
4
J6
1 2 3 4 5 6
L1
7
L2
J7
1 2 3 4 5 6 7
3
1
5
J8
J9
J12
J11
12
3
4
5
6
7
8
J10
1
234567
89
10
B
A
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
RED
WHT/RED
ON
OFF
J11
J10
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12
8
1
9
5
WHITE
24 VAC
COM
WHT
BLK/RED
BEATER
MOTOR
INTERLOCK
N.O. SWITCH
USER
INTERFACE
BOARD
- 8 LEDS
- LCD SCREEN
- 9 KEYS
- BEEPER
BLACK
BLU
WHT
BLK
BLU
BLU/WHT
BLU/WHT
RED
RED (+5v)
BLK (GRD)
HOPPER
GROUND
BLK
M
L2
L1
T1
T2
COMPRESSOR
CONTACTOR
WHT
#3 #1
240
1
L
N
TERMINAL BLOCK
BLU/WHT
BLU
BRN
HOPPER
BARREL
--THERMISTOR PROBES--
BLK
BLK
YEL
YEL
RIBBON CABLE
BLU
RED
MIX
LOW
PROBE
MIX
OUT
PROBE
PRP/WHT
PRP/WHT
GRA/BLK
RED/BLK
NO
NC
BLK
DRAW
SWITCH
COM
RED
BLU
RED
BLU
RED
BLU
WHT
WHT
WHT/ORN
RED
COMPRESSOR
CONTACTOR
COIL WHT
BLK
M
MIX
PUMP
MOTOR
BLK
OVERLOAD
SWITCH
BLU
2
3
4
WHT
RED
START
RELAY
BEATER
MOTOR
STARTER
COIL
WHT
ORN
WHT/ORN
BLK
BLK
BLK
BEATER
MOTOR
OVERLOAD
SWITCH
BLK
BLK
COMPRESSOR
HIGH PRESSURE
LIMIT SWITCH
BLK
BLK
BLK
ORN/WHT
ORN
PUR
YEL
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLK
BLU/WHT
M
T2
SOFT SERVE
COMPRESSOR
L2
L1
T1
BLK
BEATER MOTOR
STARTER
BEATER MOTOR
STARTER
BLK
SOFT SERVE
BEATER MOTOR
BLK
BLK
BLK
FUSE
15A
2
4
J2
J3
GND
+5V
J5
12
3
J6
1 2 3 4 5 6
L1
7
L2
J7
1 2 3 4 5 6 7
3
1
5
J8
J9
J12
J11
12
3
4
5
6
7
8
J10
12
3
4
5
6
7
8
9
10
B
A
J14
INTFC PCB A.
WITH SOFT SERVE
PERSONALITY PCB A.
WHT/ORN
14
13
BEATER
INTERLOCK
RELAY
4
12
8
1
9
5
BLU
WHT
BLK
BLK
M
L2
L1
T1
T2
COMPRESSOR
CONTACTOR
#3 #1
J18
1
2
J18
1
0
NOTE:
1. STATIC ELECTRICITY MAY CAUSE
DAMAGE TO SOLID STATE COMPONENTS.
ELIMINATE STATIC ELECTRICITY BY
TOUCHING GROUNDED UNIT BEFORE
HANDLING SOLID STATE COMPONENTS.
2. RED WIRE ON RIBBON CABLES MUST BE
CONNECTED TO PIN 1 AT EACH END.
GROUND FRAME SECURELY
BLK
96 95
96 95
WHT
WHT
ON
OFF
CLR (+5v)
GRN (GRD)
SV CABLE
SV CABLE
SV CABLE
SV CABLE
SV CABLE
BLU
BLU
BLU
WHT
BLK
BLK
RED
BLK
BLK
MIX REF. SYSTEM
(DANFOSS TL3G COMPR.)
M
COMP
FAN
0
1
4
1
11 13
START RELAY
START CAP
BRN
WHT
BLK
BRN
BRN
BRN
BRN
BRN
RIGHT SIDE
CONTROL
LEFT SIDE
CONTROL
BLK
BLK
BLK
BLK
BLK
BLK
WHT
WHT
GRN/YEL
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
ORN/WHT
YEL
BLU/WHT
BLU
BLU
BLK
BLU/WHT
BLU/WHT
J2
J1
GRN/YEL
GRN/YEL
GRN/YEL
ELECTRICAL
ENCLOSURE
GRN/YEL
GRN/YEL
GRN/YEL
ELECTRICAL
ENCLOSURE
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
GRN/YEL
BLU
BRN
GRN/YEL
GRN/YEL
BLK
BLK
BLK
BLK
BLK
BLK
BLK
GRN/YEL
LEFT SYRUP HEATER
WHT/RED
OPTIONAL
WHT
4
RIGHT SYRUP HEATER
RED/BLK
WHT
OPTIONAL
GRN/YEL
BRN
BLU
BRN
BLU
AIR COOLED
CONDENSER
FAN
M
BLK
BLK
GRN/YEL
WATER COOLED
1
2
3
4
T8
T1
T7
T4
T5
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
LEESON BEATER MOTOR WIRING
STEPS:
1) DISCONNECT WIRE T7 FROM TERMINAL 3
2) SPLICE BLUE WIRE AS SHOWN
1
2
4
6
BLACK
T1
CP
T2
L1
CP
L2
3
5
ORANGE INTERNAL
RED INTERNAL
YELLOW INTERNAL
BLACK INTERNAL
BLUE
T3
L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
T3
L3
USE T3 AND L3 WHEN
CP CONTACTS ARE NOT AVAILABLE
BLACK
BLUE
BEATER MOTOR
CONTACTOR
A.O. SMITH BEATER MOTOR WIRING
STEPS:
1) REMOVE BROWN JUMPER FROM BETWEEN TERMINAL #1 TO TERMINAL #5
2) MOVE BLUE INTERNAL (FROM MOTOR MAIN WINDING)
FROM TERMINAL #5 TO TERMINAL #1.
NOTE: FOR CCWLE - BLUE INTERNAL ON #1, YELLOW INTERNAL ON #6
BLUE INTERNAL
BLUE
1
2
5
4
S
R
LINE
RELAY
START CAPACITOR
C
INTERNAL OVERLOAD
RUN CAPACITOR
SCHEMATIC WIRING DIAGRAM - CSR
1
2
5
4
C
S
R
LINE
RELAY
RUN
CAP.
START CAP.
COMPRESSOR
TERMINAL
COVER
ABOVE ELECTRICAL DIAGRAM SHOWS WIRING NECESSARY
TO HOOK UP A COMPRESSOR USING A START AND RUN
CAPACITOR (CSR) WITH A RELAY.
WHITE
BROWN
BLACK
BROWN
052396-1
EQUIPMENT
GROUND
BLEED RESISTOR
WHITE(120 VOLTS)
BLACK(230 VOLTS)
BLACK
BLUE
SEE FIG. 1
FIG. 1
L1
L2
WINDING PROTECTOR
(INTERNAL)
MAIN WINDING
START WINDING
START RELAY
(047702-27)
START CAPACITOR
(047703)
COMPRESSOR WIRING
(MODEL TL3G W/HST)
11
10
13
12
14
BLACK
BLUE
BLACK
T1
CP
T2
L1
CP
L2
BEATER MOTOR
CONTACTOR
GE/RBC/MARATHON BEATER MOTOR WIRING
NOTE: FOR CCWLE - BLUE INTERNAL ON #1,YELLOW INTERNAL ON #2
BLUE
T3
L3
USE T3 AND L3 WHEN CP
CONTACTS ARE NOT AVAILABLE
J12 OR PURPLE INTERNAL
T1 OR BLUE INTERNAL
T8 OR RED INTERNAL
J9 OR BLACK INTERNAL
A
1
4
5
T4 OR YELLOW INTERNAL
2
FIG. 3
FIG. 2
SEE FIG. 3
SEE FIG. 2
SEE FIG. 3
SEE FIG. 2
CLR
BLK
BLK/RED
BLK/RED
BARREL LIQUID
SOLENOID
WHT
GRY/WHT
BARREL LIQUID
SOLENOID
WHT
GRY/WHT
GRN/YEL
GRN/YEL
BLK
CL
CL
EQUIPOTENTIAL
GROUND
A
A
A
A
UVC4
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
JP1
PINS 1 AND 2
JUMPER INSTALLED- BARREL AND HOPPER
TEMPERATURES ARE CHECKED DURING
AUTO/STANDBY. UNIT IS LOCKED OUT IF
EITHER BARREL OR HOPPER IS TOO WARM FOR
A PERIOD OF TIME. LOCKOUT OCCURS WHEN
BARREL OR HOPPER IS ABOVE 45
F (7
C)
FOR MORE THAN ONE HOUR OR ABOVE 41
F
(5
C) FOR MORE THAN FOUR HOURS.
YES
NO JUMPER INSTALLED-NO LOCKOUT DURING
AUTO/STANDBY IF BARREL OR HOPPER IS TOO
WARM FOR A PERIOD OF TIME.
PINS 3 AND 4
RESERVED (DO NOT USE)
NO
JP2
PINS 1 AND 2
DOMESTIC CONFIGURATION-JUMPER INSTALLED.
HOPPER TEMPERATURE NOT DISPLAYED ON
SCREEN/HEAT SYMBOL KEYS ONLY ACTIVE
WHEN A LOCKOUT CONDITION HAS OCCURRED/
STANDBY KEYS DISABLED.
NO
INTERNATIONAL CONFIGURATION-NO JUMPER
INSTALLED. HOPPER TEMPERATURES
DISPLAYED ON SCREEN/MANUAL HEAT CYCLE
START BY SELECTING HEAT SYMBOL/STANDBY
KEYS FUNCTIONAL.
JP3
RESERVED (DO NOT USE)
NO
JP4
RESERVED (DO NOT USE)
NO
JP5
RESERVED (DO NOT USE)
NO
JP6
RESERVED (DO NOT USE)
NO
JP7
JUMPER INSTALLED DISABLES RESET.
NO
RTCK
RESERVED (DO NOT USE)
NO
DBGEN
RESERVED (DO NOT USE)
NO
LEFT INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1
RESERVED (DO NOT USE)
NO
W2
JUMPER INSTALLED-FORCE BRUSH CLEAN STATUS.
NO
W3
JUMPER INSTALLED-ACTIVATES SYRUP HEATERS.
NO*
W4
RESERVED (DO NOT USE)
NO
W5
RESERVED (DO NOT USE)
NO
W6
JUMPER INSTALLED-REDUCED MIX LOW SENSITIVITY.
NO
W7
JUMPER INSTALLED-REDUCED MIX OUT SENSITIVITY.
NO
J10
PINS 7 & 8
JUMPER INSTALLED W/SWITCH-SELF SERVE
APPLICATION ONLY. LOCKS OUT TOUCH
PANEL. NEW SWITCH ACTS AS THE ON/OFF
ABILITY TO ACTIVATE THE TOUCH PANEL.
NO
A
SOFT SERVE
PERSONALITY
BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE
NO
B
SOFT SERVE
PERSONALITY
BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE
YES
RIGHT INTERFACE
BOARD
FUNCTION
JUMPER
INSTALLED
INITIALLY
W1
RESERVED (DO NOT USE)
NO
W2
JUMPER INSTALLED-ENABLES 59
F HOPPER
TEMPERATURE CHECK.
YES
W3
RESERVED (DO NOT USE)
NO
W4
RESERVED (DO NOT USE)
NO
W5
RESERVED (DO NOT USE)
NO
W6
JUMPER INSTALLED-REDUCED MIX LOW SENSITIVITY.
NO
W7
JUMPER INSTALLED-REDUCED MIX OUT SENSITIVITY.
NO
A
SOFT SERVE
PERSONALITY
BOARD
0-6 AMP BEATER MOTOR AMPERAGE RANGE
NO
B
SOFT SERVE
PERSONALITY
BOARD
0-12 AMP BEATER MOTOR AMPERAGE RANGE
YES
A
B
A
B
J13 J1
J13 J1
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
DRAW
SWITCH
C0M
PANEL
JACK
NO
NC
RED
BLK
DRAW
SWITCH
C0M
NO
NC
ADDITIONAL DRAW SWITCH
FOR FLAVORBURST
PANEL
JACK
RED
BLK
WHT
BLK/RED
WHT
WHT
SEE FIG. 4
SEE FIG. 4
SYRUP HEATER
THERMOSTA
190 F OPEN
140 F CLOSE
WHT
WHT
WHT
WHT
O.T.
FIG .4
SELF-SERVICE
ENABLE
ENABLE
DISABLE
(OPTIONAL)
BLK
J1
1
2
GRD
+5V
CLR
J2
J7
UNIVERSAL CONTROL PCB A.
J9
J12
J17
J15
J8
5
4
6
2
1
3
J13
J4
J16
CABLE
RED
GRN WHT
BLK
RIBBON CABLE
RIBBON CABLE
J3
* IF THE UNIT HAS THE INTEGRAL SYRUP OPTION-405, THEN THIS
JUMPER SHOULD BE INSTALLED.
JUMPER SETTINGS
CABLE
OPTIONAL REAR
MIX LEVEL LIGHTS
IN
2
1
4
3
6
5
8
7 10
9
OUT
2
1
4
3
6
5
8
7 10
9
J19 1
2
J20
J19 1
2
J20
CABLE
CABLE
CABLE
CABLE
Содержание C712
Страница 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Страница 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Страница 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Страница 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Страница 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Страница 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Страница 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...
Страница 91: ...Section 5 5 1 Models C712 C713 Parts List Parts List C71227F000 C71327F000 50HZ 60HZ w High V 50HZ ...
Страница 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...