INTRODUCTION
1-13
Models C712/C713
Introduction
1
Syrup Rail Operating Instructions
1. Remove the stainless steel syrup jar with topping
pump from the syrup rail. Check the water level in the
well. Make sure the water is filled to the indicating
mark on the inside wall (16 oz. [454 g]). Check the
water level daily.
2. Place the heater switch in the ON position. The
heating process will take approximately 1-1/4 hours.
3. Prepare a pail with an approved 100 PPM sanitizing
solution.
Important! Use warm water and follow the
manufacturer's specifications.
4. Sanitize the pump by placing the entire assembly in
the solution and pump the solution through the pump
until sanitized.
5. Fill the heated and room temperature syrup jars with
toppings. Place the topping pump in the heated syrup
jar. Sanitize the ladle and place it in the room
temperature jar.
Environmental Notices
CAUTION!
In consideration of our
environment, Taylor uses only earth-friendly HFC
refrigerants. The HFC refrigerant used in this machine is
R404A. This refrigerant is generally considered nontoxic
and nonflammable, with an ozone-depleting potential
(ODP) of zero (0). However, any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion.
IMPORTANT! If the crossed-out waste
container symbol is affixed to this product, it signifies that
this product is compliant with the EU Directive as well as
other similar legislation in effect after August 13, 2005.
Therefore, it must be collected separately after its use is
completed, and cannot be disposed as unsorted
municipal waste.
The user is responsible for delivering the product to the
appropriate collection facility, as specified by your local
code.
For additional information regarding applicable local
laws, please contact the municipal facility and/or local
distributor.
NOISE LEVEL:
Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of
1.0 meter from the surface of the machine at a height of
1.6 meters from the floor.
Содержание C712
Страница 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Страница 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Страница 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Страница 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Страница 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Страница 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Страница 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...
Страница 91: ...Section 5 5 1 Models C712 C713 Parts List Parts List C71227F000 C71327F000 50HZ 60HZ w High V 50HZ ...
Страница 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...