C712/C713 UVC4 Update Instructions
Estimated Time: 35 minutes
Important!
•
See “UVC4 Electrostatic Discharge and Proper
Handling Procedures” on page 2-22 before han-
dling a UVC4 board.
•
Before performing software update, reset the
control to defaults. This will clear the RAM mem-
ory so the new software can be loaded.
•
Only use factory supplied USB drives to perform
software update. Do not make copies of factory
supplied USB drives with generic USB drives.
Failure to follow this instruction can cause
issues in successfully completing the software
update.
•
Wear appropriate personal protective
equipment.
1. Enter the Service menu (5231) to copy the current
machine settings.
2. Place both sides of the machine in the OFF mode
and turn the syrup heaters off.
CAUTION!
Disconnect all power to the
machine. Failure to follow this instruction may result in
electrocution.
3.
4. Remove the two drip trays from the upper rear of the
machine and place them on top of the machine.
5. Remove the two screws at the bottom of the
Panel-Rear-Upper.
6. Remove the six screws from the Cover-Control Box.
7. Install a jumper on the W2 on the left side interface
board.
8. Reconnect power to the machine and turn power on.
Verify that the display says UNIT CLEANED.
9. Remove the jumper from W2 on the left side interface
board.
10. Enter the Service Menu and go to the option, Reset
to Defaults.
11. Perform a Reset to Defaults by selecting YES to
clear all RAM memory.
12. Install the USB flash drive in the J4 port on the UVC4
board.
13. Check jumper position JP7. Remove the jumper, if
present, and do not reinstall.
14. Access the Service Menu. Go to Software Update
and select YES to begin update process.
15. Wait 3 minutes for the software to complete the
update.
16. After the Lamp Test, enter the Service Menu and
clear any faults. Reset unit to defaults.
17. Re-enter all settings copied earlier.
18. Remove the USB flash drive from the UVC4 board
and store it in the tool kit.
19. Place both sides of the unit in the Auto mode. Turn
the syrup heaters back on, if that was the original
state before the installation.
20. Verify both sides of the machine are operating
properly (shutting off at proper viscosity and no
faults).
21. Draw at least one soft serve cone per side to verify
that the product appearance is acceptable
22. Carefully reinstall the control box cover, back panel,
and drip trays.
Содержание C712
Страница 9: ...INTRODUCTION 1 5 Models C712 C713 Introduction 1 Figure 1 1 ...
Страница 11: ...INTRODUCTION 1 7 Models C712 C713 Introduction 1 Figure 1 2 ...
Страница 22: ...1 18 INTRODUCTION Models C712 C713 Introduction 1 Notes ...
Страница 42: ...2 20 CONTROLS Models C712 C713 Controls 2 Control Overview UVC4 Figure 2 58 ...
Страница 48: ...2 26 CONTROLS Models C712 C713 Controls 2 Refrigeration Schematic Figure 2 62 ...
Страница 50: ...2 28 CONTROLS Models C712 C713 Controls 2 Notes ...
Страница 60: ...3 10 TROUBLESHOOTING Models C712 C713 Troubleshooting 3 Notes ...
Страница 91: ...Section 5 5 1 Models C712 C713 Parts List Parts List C71227F000 C71327F000 50HZ 60HZ w High V 50HZ ...
Страница 120: ...6 10 WIRING DIAGRAMS Models C712 C713 Wiring Diagrams 6 Notes ...