Page 59
B5-440-36 / B5-440-48 / B5-540-48XL / BF-030-48Operator Manual
MB-440-07
1) Ammeter
•
Solid
: Displays scale of output during bulk phase.
•
Flashing
: Output has been reduced due to high
internal charger temperature.
•
No battery connected
: Displays charge profiles
1-6.
2) Bulk Charge Indicator
•
Solid
: Bulk charge phase completed (80% charged)
and is in absorption phase.
•
Flashing
: Displays charge profile number if no
battery is connected.
3) Charge Completion Indicator
•
Solid
: Charging complete and maintenance mode
is active.
•
Flashing
: Absorption phase completed and is in
finishing phase.
4) AC Indicator
•
Solid
: AC power is present.
•
Flashing
: Low AC voltage. Refer to qualified
technician.
5) Fault Indicator
•
Charger fault. Refer to troubleshooting information
below.