B5-440-36 / B5-440-48 / B5-540-48XL / BF-030-48 Operator Manual
MB-440-07
Troubleshooting Instructions
If a fault occurs, count the number of flashes between
pauses and refer to the table below.
Note: If there is no discernible pause then it is an indication
of fault code 1.
FLASHES
CAUSE
SOLUTION
1
High battery voltage
Check battery size and condition.
This fault will clear automatically
once the condition has been
corrected.
2
Low battery voltage
Check battery size and condition.
This fault will clear automatically
once the condition has been
corrected.
3
Charge time out caused by
battery pack not reaching
required voltage or charger
output reduced due to high
temperatures.
Check battery connections.
Confirm that the battery type
matches selected charge profile
Operate the charger at a lower
ambient temperature.
Reset the charger by interrupting AC
power for 15+ seconds.
4
Battery could not be trickle
c h a r g e d u p t o m i n i m u m
voltage.
Check for shorted or damaged cells.
Reset the charger by interrupting
power for 15+ seconds.
5
Charger shutdown due to high
internal temperature.
Ensure sufficient cooling airflow.
Reset the charger by interrupting AC
power for 15+ seconds.
6
Internal charger fault
Reset the charger by interrupting
AC power for 15+ seconds. Refer to
qualified technician if fault persists.