TATSUNO
EUROPE
a.s.,
www.tatsuno
‐
europe.com
38
Code
of
message
Type
of
message
Cause
of
error
message
Removing
error
message
E74
NFAT
Mass
meter
configuration
error
Turn
the
power
supply
of
the
dispenser
off
and
on.
If
the
fault
persists,
call
an
authorized
service
centre.
E75
NFAT
Mass
meter
zero
point
setting
error
E76
NFAT
Damaged
stored
value
of
the
meter
zero
point
E80
NFAT
The
display
serial
number
does
not
match
E81
NFAT
The
serial
number
of
the
auxiliar
display
does
not
match
E82
NFAT
The
serial
number
of
the
electromechanical
totalizer
unit
E83
NFAT
The
serial
number
of
the
PDEINP
temperature
sensors
unit
does
not
match.
E84
NFAT
The
serial
number
of
the
mass
meter
does
not
match
E85
NFAT
The
serial
number
of
the
PDEDPS
pressure
sensors
unit
does
not
match.
E86
NFAT
Insufficient
LPG
pressure
difference
E87
NFAT
Electromechanical
totalizer
coil
failure
6.3.
SERVICE
OF
DISPENSERS
service
work
is
carried
out
in
accordance
with
the
operating
rules
at
the
fuel
station
before
starting
the
service,
the
dispenser
must
be
shut
down,
marked
visibly
with
the
"OUT
OF
SERVICE"
sign
and
the
driveway
must
be
marked
with
the
"NO
ENTRY”
sign
the
dispenser
must
be
disconnected
from
the
power
supply
(switch
off
by
the
main
switch
on
the
switchboard)
the
valves
on
the
supply
line
must
be
fully
closed
during
service
work,
vehicles
must
be
prevented
from
passing
within
5
meters
around
a
fire
extinguisher
must
be
available
to
workers
service
work
may
only
be
performed
by
an
authorized
service
agent
6.3.1.
WARRANTY
AND
COMPLAINTS
The
contractual
warranty
is
determined
–
by
default,
the
manufacturer
provides
warranty
for
provided
devices
for
2
years.
This
warranty
does
not
cover
consumables.
In
case
of
any
complaints
the
following
information
must
be
specified:
Serial
number
and
type
–
see
the
type
label
Exact
description
of
the
defect
and
circumstances
of
its
occurrence
The
complaint
shall
be
invalid
if
the
safety
seals
are
broken
or
the
device
has
been
tampered
with.
Defects
and
deficiencies
caused
by
incorrect
or
unauthorized
use
or
maintenance
are
not
covered
by
the
warranty
(e.g.,
problems
caused
due
to
the
water
content
and
impurities
in
the
tank
and
hydraulic
system).
During
operation,
it
is
necessary
to
regularly
check
water
and
impurities
presence
and
perform
cleaning
if
necessary.
6.3.2.
ACCESSORIES
Quick
User
Guide
Certificate
on
product
quality
and
completeness
&
EU
Declaration
of
conformity
Data
sheet
of
the
dispenser
&
Logbook
of
all
meters
installed
in
the
dispenser
Pressure
test
protocol
IR
controller
for
counter
operation
and
setting
&
Foundation
frame
(may
be
ordered)
Spare
parts
catalogue.
The
document
is
intended
for
service
companies
and
service
engineers
only.