background image

TATSUNO

 

EUROPE

 

a.s.,

 

www.tatsuno

europe.com

 

 

 

32

5.3.2.

 

ELECTROMECHANICAL

 

TOTALIZERS

 

On

 

demand,

 

TATSUNO

 

EUROPE

 

dispensers

 

are

 

equipped

 

with

 

electromechanical

 

totalizers

 

for

 

monitoring

 

the

 

total

 

amount

 

of

 

fuel

 

flown

 

through

 

each

 

delivery

 

hose.

 

Totalizers

 

are

 

located

 

on

 

the

 

dispenser

 

display.

 

Each

 

delivery

 

hose

 

or

 

nozzle

 

has

 

one

 

seven

digit

 

electromechanical

 

totalizer

 

that

 

shows

 

the

 

number

 

of

 

complete

 

kilograms

 

delivered

 

through

 

the

 

appropriate

 

delivery

 

hose.

 

For

 

multiple

 

product

 

dispensers,

 

the

 

electromechanical

 

totalizers

 

on

 

the

 

display

 

are

 

ordered

 

from

 

top

 

to

 

bottom

 

or

 

from

 

left

 

to

 

right

 

and

 

are

 

marked

 

with

 

delivery

 

hose

 

numbers.

  

NOTE

 

On

 

display

 

A,

 

the

 

electromechanical

 

totalizers

 

are

 

numbered

 

1,

 

2,

 

3,

 

4.

 

The

 

numbers

 

of

 

the

 

totalizers

 

correspond

 

to

 

the

 

delivery

 

hoses

 

1A,

 

2A,

 

3A

 

and

 

4A.

 

On

 

the

 

display

 

B,

 

the

 

electromechanical

 

totalizers

 

are

 

also

 

numbered

 

1,

 

2,

 

3,

 

4.

 

The

 

numbers

 

of

 

totalizers

 

correspond

 

to

 

the

 

delivery

 

hoses

 

1B,

 

2B,

 

3B

 

and

 

4B.

 

 

5.3.3.

 

DISPENSER

 

OPERATING

 

MODES

 

There

 

are

 

two

 

basic

 

dispenser

 

operating

 

modes:

 

1)

 

manual

 

mode

 

2)

 

automatic

 

(remote)

 

mode

 

The

 

manual

 

mode

 

is

 

a

 

status

 

when

 

the

 

dispenser

 

works

 

independently

 

of

 

any

 

remote

 

control.

 

Delivery

 

progress:

 

The

 

customer

 

arrives

 

at

 

the

 

dispensers

 

takes

 

the

 

delivery

 

nozzle

 

(connector),

 

inserts

 

it

 

into

 

car

 

and

 

presses

 

button

 

START.

 

The

 

display

 

resets

 

(approx.

 

1.5

 

seconds)

 

and

 

the

 

gas

 

filling

 

starts.

 

Once

 

the

 

fuel

 

has

 

been

 

delivered,

 

the

 

customer

 

disconnects

 

delivery

 

nozzle

 

from

 

the

 

car,

 

hangs

 

up

 

the

 

nozzle

 

into

 

dispenser

 

and

 

pays

 

for

 

the

 

delivered

 

fuel

 

to

 

the

 

station

 

operator.

 

The

 

dispenser

 

is

 

immediately

 

ready

 

for

 

next

 

delivery.

  

Since

 

the

 

dispenser

 

is

 

not

 

controlled

 

in

 

any

 

way

 

in

 

the

 

manual

 

mode,

 

it

 

is

 

necessary

 

to

 

manually

 

set

 

the

 

fuel

 

unit

 

price

 

on

 

the

 

dispenser

 

 

see

 

sections

 

4.1.7.

 

The

 

number

 

of

 

delivered

 

litres

 

per

 

shift

 

is

 

determined

 

by

 

the

 

difference

 

between

 

the

 

electronic

 

(or

 

electromechanical)

 

totalizers

 

at

 

the

 

start

 

and

 

end

 

of

 

the

 

shift.

 

The

 

automatic

 

mode

 

is

 

a

 

status

 

when

 

the

 

dispenser

 

is

 

remotely

 

controlled

 

by

 

a

 

control

 

device

 

(program

 

in

 

PC,

 

control

 

device,

 

station

 

controller,

 

etc.).

 

The

 

automatic

 

mode

 

allows

 

remotely

 

control

 

deliveries

 

from

 

the

 

fuel

 

station

 

booth.

 

The

 

booth

 

contains

 

a

 

control

 

device

 

by

 

which

 

the

 

fuel

 

station

 

attendant

 

releases

 

the

 

dispenser

 

for

 

delivery

 

and

 

collects

 

information

 

about

 

the

 

delivered

 

fuel

 

amount

 

and

 

price

 

after

 

the

 

delivery

 

is

 

finished.

 

Delivery

 

progress:

 

The

 

customer

 

arrives

 

at

 

the

 

dispensers,

 

takes

 

the

 

delivery

 

nozzle,

 

inserts

 

it

 

into

 

car

 

and

 

presses

 

button

 

START.

 

The

 

dispenser

 

requires

 

filling

 

authorization

 

from

 

the

 

control

 

unit

 

in

 

the

 

booth.

 

The

 

control

 

unit

 

sends

 

authorisation

 

command

 

together

 

with

 

fuel

 

unit

 

price

 

and

 

maximum

 

amount/quantity

 

of

 

delivery.

 

The

 

display

 

of

 

the

 

dispenser

 

resets

 

(*approx.

 

2

 

seconds

 

after

 

removing

 

the

 

nozzle)

 

and

 

the

 

gas

 

filling

 

starts.

 

Once

 

the

 

fuel

 

has

 

been

 

delivered,

 

the

 

customer

 

disconnects

 

delivery

 

nozzle

 

from

 

the

 

car,

 

hangs

 

up

 

the

 

nozzle

 

into

 

dispenser

 

and

 

pays

 

the

 

required

 

amount

 

to

 

the

 

booth

 

where

 

he

 

receives

 

the

 

tax

 

receipt

 

(receipt)

 

for

 

the

 

delivered

 

fuel.

 

The

 

dispenser

 

is

 

immediately

 

ready

 

for

 

next

 

delivery.

 

Since

 

the

 

dispenser

 

is

 

remotely

 

controlled

 

in

 

the

 

automatic

 

mode,

 

it

 

is

 

not

 

necessary

 

to

 

manually

 

set

 

the

 

fuel

 

unit

 

price

 

on

 

the

 

dispenser.

 

The

 

correct

 

unit

 

price

 

is

 

automatically

 

set

 

by

 

the

 

control

 

computer

 

to

 

all

 

dispensers

 

at

 

the

 

fuel

 

station.

 

Switch

 

from

 

the

 

automatic

 

to

 

the

 

manual

 

mode.

 

By

 

default,

 

the

 

dispensers

 

are

 

connected

 

and

 

set

 

as

 

it

 

is

 

expected

 

they

 

should

 

work

 

at

 

the

 

fuel

 

station,

 

i.e.,

 

if

 

the

 

fuel

 

station

 

is

 

equipped

 

with

 

a

 

control

 

system,

 

the

 

dispensers

 

will

 

be

 

set

 

to

 

the

 

automatic

 

mode;

 

if

 

the

 

fuel

 

station

 

is

 

without

 

the

 

control

 

system,

 

the

 

dispensers

 

are

 

set

 

to

 

the

 

manual

 

mode

 

by

 

default.

 

In

 

case

 

you

 

have

 

to

 

switch

 

the

 

dispensers

 

from

 

automatic

 

to

 

manual

 

mode

 ‐ 

e.g.,

 

because

 

of

 

a

 

crash

 

in

 

the

 

control

 

system,

 

you

 

have

 

to

 

change

 

the

 

value

 

of

 

parameter

 

M0

P12

 

from

 

value

 

0

 

to

 

value

 

3

 

using

 

the

 

IR

 

remote

 

control

 

and

 

to

 

check

 

the

 

setting

 

of

 

unit

 

prices

 

in

 

parameter

 

M0

P03

 

 

see

 

chapters

 

4.1.7.

 

NOTICE

 

The

 

switch

 

from

 

the

 

automatic

 

to

 

manual

 

mode

 

must

 

be

 

discussed

 

with

 

the

 

service

 

engineer

 

in

 

advance!

 

5.3.4.

 

PRESET

 

KEYPAD

 

TATSUNO

 

EUROPE

 

dispensers

 

may

 

be

 

equipped

 

with

 

a

 

so

called

 

preselection

 

keypad

 

enabling

 

preset

 

the

 

delivered

 

amount

 

or

 

quantity

 

(volume

 

or

 

weight)

 

by

 

the

 

customer

 

directly

 

on

 

the

 

dispenser.

 

The

 

customer

 

may

 

decide

 

before

 

he/she

 

starts

 

Содержание EUROPE

Страница 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Страница 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Страница 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Страница 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Страница 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Страница 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Страница 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Страница 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Страница 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Страница 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Страница 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Страница 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Страница 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Страница 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Страница 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Страница 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Страница 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Страница 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Страница 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Страница 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Страница 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Страница 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Страница 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Страница 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Страница 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Страница 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Страница 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Страница 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Страница 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Страница 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Страница 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Страница 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Страница 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Страница 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Страница 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Страница 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Страница 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Страница 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...

Отзывы: