background image

CNG

 

dispensers

 

TATSUNO

 

EUROPE

 ‐ 

Quick

 

User

 

Guide

 

,

 

revision

 

01,

 

March

 

2022

 

 

 

 

15

2.6.

 

NAMEPLATES

 

Each

 

dispenser

 

is

 

equipped

 

with

 

one,

 

see

 

Figure

 

7,

 

or

 

in

 

the

 

case

 

of

 

a

 

combined

 

dispenser,

 

with

 

several

 

nameplates

 

for

 

individual

 

fuels,

 

see

 

Chyba!

 

Nenalezen

 

zdroj

 

odkaz

ů

.

.

 

If

 

the

 

number

 

of

 

delivery

 

hoses

 

is

 

higher

 

than

 

two

 

then

 

the

 

dispenser

 

is

 

supplemented

 

with

 

the

 

so

called

 

orientation

 

label,

 

see

 

Figure

 

9,

 

where

 

it

 

is

 

schematically

 

indicated

 

what

 

kind

 

of

 

fuel

 

is

 

pumped

 

and

 

with

 

what

 

hose.

 

All

 

data

 

on

 

the

 

dispenser

 

in

 

terms

 

of

 

metrology

 

and

 

safety

 

according

 

to

 

WELMEC

 

10.5

 

and

 

European

 

standards

 

for

 

equipment

 

located

 

in

 

potentially

 

explosive

 

areas

 

(EN

 

13617

1,

 

EN

 

14678

1,

 

EN

 

IEC

 

60079

0

 

and

 

EN

 

ISO

 

80079

36)

 

is

 

contained

 

in

 

the

 

nameplate.

 

At

 

the

 

same

 

time,

 

the

 

orientation

 

label

 

serves

 

to

 

metrology

 

inspection

 

for

 

sticking

 

the

 

safety

 

metrology

 

labels

 

stating

 

the

 

execution

 

of

 

measuring

 

system

 

verification.

 

     

     

 

        

        

      

 

Table

 

2

 ‐ 

Label

 

information

 

on

 

the

 

dispenser

 

and

 

module

 

TATSUNO

 

EUROPE

 

a.s.

 

Name

 

and

 

address

 

of

 

dispenser

 

manufacturer

 

 

Dispenser

 

labelling

 

means

 

that

 

it

 

is

 

designed,

 

manufactured

 

and

 

labelled

 

in

 

accordance

 

with

 

European

 

Commission

 

directives.

 

CNG

 

DISPENSER

 

Device

 

identification

 

Type

 

of

 

Marking

 

of

 

the

 

dispenser

 

type

 

(see

 

section

 

2.3)

 

OIML

 

certificate

 

Number

 

of

 

the

 

OIML

 

certificate

 

Serial

 

number

 

Serial

 

number

 

of

 

the

 

dispenser

 

(seq.

 

number

 

/

 

year

 

of

 

production)

 

Gas

 

temperature

 

range

 

Range

 

of

 

gas

 

temperature

 

for

 

which

 

the

 

dispenser

 

was

 

designed

 

and

 

approved

 

Ambient

 

temperature

 

range

 

Range

 

of

 

ambient

 

temperature

 

for

 

which

 

the

 

dispenser

 

was

 

designed

 

and

 

approved

 

Pressure

 

min/max

 

Minimum

 

and

 

maximum

 

working

 

pressure

 

Accuracy

 

class/mech/elm.

 

Accuracy

 

class

 

/

 

Mechanical

 

class

 

/

 

Electromagnetic

 

class

 

CNG

 

Type

 

of

 

gas

 

for

 

which

 

the

 

dispenser

 

was

 

designed

 

and

 

approved

 

Q

max

  

Maximum

 

pumping

 

/

 

filling

 

flow

 

rate

 

in

 

kg/min

 

Q

min

  

Minimum

 

pumping

 

/

 

filling

 

flow

 

rate

 

in

 

kg/min

 

MMQ

  

Minimum

 

consumption

 

in

 

kg

 

 

II

 

2G

 

IIA

 

T3

 

Identification

 

of

 

the

 

protection

 

of

 

a

 

non

explosive

 

electrical

 

device:

 

II

 

2

 

 

device

 

for

 

environment

 

with

 

an

 

explosion

 

hazard

 

other

 

than

 

subsurface

 

mines,

 

probability

 

of

 

explosive

 

atmosphere

 

occurrence

 

 

zone

 

1

 

G

 

 

explosive

 

atmosphere

 

is

 

formed

 

by

 

gases,

 

vapours

 

or

 

mists

 

IIA

 

 

gas

 

group

 

 

the

 

least

 

dangerous

 

T3

 

 

maximum

 

temperature

 

of

 

an

 

electrical

 

device

 

that

 

could

 

cause

 

ignition

 

of

 

the

 

ambient

 

atmosphere

 

(200°C)

 

EN

 

60079

0;

 

EN

 

80079

36

 

Number

 

of

 

the

 

European

 

standard

 

under

 

which

 

the

 

dispenser

 

was

 

approved

 

Figure

 

7

 ‐ 

Nameplate

 

of

 

a

 

two

hose

 

CNG

 

dispenser

 

Figure

 

8

 ‐ 

Nameplate

 

of

 

the

 

multi

hose

 

CNG

 

dispenser

 

Figure

 

9

 ‐ 

Orientation

 

label

 

for

 

multiple

 

hose

 

CNG

 

dispensers

 

Содержание EUROPE

Страница 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Страница 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Страница 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Страница 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Страница 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Страница 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Страница 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Страница 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Страница 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Страница 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Страница 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Страница 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Страница 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Страница 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Страница 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Страница 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Страница 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Страница 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Страница 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Страница 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Страница 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Страница 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Страница 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Страница 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Страница 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Страница 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Страница 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Страница 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Страница 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Страница 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Страница 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Страница 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Страница 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Страница 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Страница 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Страница 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Страница 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Страница 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...

Отзывы: