background image

TATSUNO

 

EUROPE

 

a.s.,

 

www.tatsuno

europe.com

 

 

 

30

NOTICE

 

After

 

start

up

 

of

 

calculator

 

TBELTM

 

and

 

before

 

every

 

delivery

 

transaction

 

are

 

checked

 

values

 

of

 

the

 

registers

 

inside

 

mass

 

meter

 

if

 

they

 

are

 

equal

 

with

 

values

 

saved

 

in

 

calculator

 

memory.

 

If

 

not,

 

error

 

code

 

E74

 

is

 

appeared

 

on

 

display

 

and

 

delivery

 

is

 

not

 

allowed.

 

To

 

disable

 

the

 

error

 

is

 

necessary

 

to

 

perform

 

function

 

P99

 

=

 

4444

 

again.

 

 

NOTICE

 

To

 

run

 

function

 

mass

 

meter

 

configuration

 

is

 

necessary

 

to

 

press

 

<R>

 

on

 

yellow

 

service

 

remote

 

transmitter

 

PDERT

5S,

 

enter

 

service

 

password

 

(factory

 

setting

 

11111111)

 

followed

 

by

 

key

 

<E>.

 

In

 

Service

 

mode

 

of

 

calculator

 

is

 

necessary

 

to

 

press

 

99

 

with

 

<E>

 

to

 

go

 

on

 

parameter

 

99

 

and

 

after

 

press

 

<E>

 

again,

 

enter

 

value

 

4444

 

and

 

<E>.

 

If

 

function

 

passed

 

OK

 

then

 

message

 

„done

 

“appeared

 

for

 

a

 

while.

 

5.3.

 

DISPENSER

 

OPERATION

 

 

NOTICE

 

The

 

operator

 

is

 

responsible

 

for

 

the

 

operation

 

of

 

the

 

fuel

 

station

 

and

 

it

 

is

 

his

 

duty

 

to

 

monitor

 

the

 

delivery

 

of

 

fuel

 

and,

 

in

 

the

 

event

 

that

 

the

 

customer

 

performs

 

unauthorized

 

operations

 

at

 

the

 

self

service

 

dispensers,

 

he

 

must

 

instruct

 

the

 

customer

 

about

 

proper

 

handling.

 

The

 

operator

 

is

 

also

 

obliged

 

to

 

mark

 

the

 

risk

 

area

 

of

 

the

 

fuel

 

station

 

with

 

warning

 

symbols

 

(smoking

 

ban,

 

ban

 

on

 

open

 

fire,

 

direction

 

of

 

arrival

 

to

 

the

 

dispenser,

 

etc.).

 

The

 

fuel

 

station

 

operating

 

instructions

 

must

 

be

 

freely

 

accessible

 

to

 

the

 

customer

 

for

 

any

 

information

 

on

 

basic

 

obligations.

 

5.3.1.

 

CNG

 

DELIVERY

 

TO

 

MOTOR

 

VEHICLES

 

Delivery

 

start

 

Before

 

the

 

delivery

 

starts,

 

the

 

dispenser

 

attendant

 

checks

 

whether

 

the

 

storage

 

tank

 

in

 

a

 

vehicle

 

has

 

a

 

homologation

 

mark,

 

the

 

vehicle

 

engine

 

and

 

all

 

electrical

 

devices

 

are

 

turned

 

off.

 

Then

 

he/she

 

visually

 

inspects

 

the

 

condition

 

or

 

wear

 

of

 

the

 

filling

 

neck/connector

 

that

 

could

 

be

 

the

 

reason

 

for

 

leaks.

 

If

 

he/she

 

finds

 

serious

 

deficiencies,

 

he/she

 

is

 

entitled

 

to

 

refuse

 

storage

 

tank

 

filling.

 

In

 

case

 

of

 

gas

 

leak

 

or

 

danger

 

the

 

attendant

 

shall

 

finish

 

the

 

delivery.

 

The

 

operation

 

of

 

the

 

dispenser

 

itself

 

is

 

ensured

 

by

 

the

 

employee

 

of

 

the

 

fuel

 

station

 

who

 

lifts

 

the

 

delivery

 

nozzle

 

from

 

the

 

dispenser

 

and

 

connects

 

it

 

to

 

the

 

storage

 

tank

 

of

 

the

 

vehicle

 

which

 

must

 

be

 

secured

 

against

 

moving.

 

Immediately

 

after

 

the

 

nozzle

 

is

 

lifted

 

the

 

display

 

test

 

is

 

performed

 

 

displaying

 

all

 

segments

 

 

and

 

then

 

it

 

is

 

reset

 

and

 

the

 

product

 

unit

 

price

 

is

 

displayed.

 

 

After

 

pressing

 

the

 

START

 

button

 

located

 

on

 

the

 

counter

 

case

 

the

 

electromagnetic

 

valve

 

opens

 

at

 

the

 

inlet

 

of

 

the

 

first

 

pressure

 

section

 

and

 

the

 

pressure

 

storage

 

tank

 

of

 

the

 

vehicle

 

is

 

filled

 

with

 

compressed

 

natural

 

gas.

 

In

 

the

 

moment

 

when

 

the

 

delivery

 

speed

 

decreases

 

under

 

the

 

defined

 

limit,

 

the

 

electronic

 

counter

 

automatically

 

switches

 

delivery

 

to

 

the

 

second

 

section

 

and

 

then

 

potentially

 

to

 

the

 

third

 

pressure

 

section

 

 

depending

 

on

 

the

 

dispenser

 

and

 

fuel

 

station

 

configuration.

  

NOTE

   

Some

 

dispensers,

 

especially

 

non

public

 ‐ 

company

 

dispensers,

 

are

 

not

 

fitted

 

with

 

the

 

sensors

 

of

 

delivery

 

nozzle

 

lifting.

 

At

 

such

 

dispensers,

 

the

 

display

 

test

 

is

 

performed

 

after

 

pressing

 

the

 

START

 

button.

 

Delivery

 

termination

 

The

 

delivery

 

may

 

be

 

terminated

 

for

 

various

 

causes.

 

Possible

 

causes

 

of

 

delivery

 

termination

 

and

 

corresponding

 

messages

 

shown

 

on

 

the

 

display

 

are

 

mentioned

 

in

 

table

 

below

 

Table

 

4

 ‐ 

Causes

 

for

 

delivery

 

termination

 

Event

 

Indication

 

on

 

display

 

1.

 

Pressing

 

the

 

STOP

 

button

 

by

 

the

 

customer/attendant

 

during

 

the

 

delivery

 

STOP

 

2.

 

Attaining

 

the

 

pre

set

 

sum,

 

quantity,

 

or

 

limit

 

values

 

of

 

the

 

dispenser

 

STOP

 

3.

 

STOP

 

command

 

received

 

from

 

the

 

superior

 

system

 

(payment

 

terminal)

 

STOP

 

4.

 

Gas

 

flow

 

rate

 

drop

 

under

 

the

 

value

 

set

 

on

 

the

 

dispenser

 

(e.g.,

 

<

 

2kg/min)

 

FULL

 

5.

 

Attaining

 

the

 

maximum

 

possible

 

mass

 

calculated

 

by

 

temperature

 

compensation

 

FULL

 

6.

 

Detection

 

of

 

an

 

error

 

event.

 

Exx

 

  

8888888

 

1888888

 

 

88888

 

  

0.0

 

0.000

 

 

26.50

 

Содержание EUROPE

Страница 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Страница 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Страница 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Страница 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Страница 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Страница 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Страница 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Страница 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Страница 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Страница 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Страница 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Страница 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Страница 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Страница 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Страница 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Страница 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Страница 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Страница 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Страница 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Страница 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Страница 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Страница 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Страница 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Страница 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Страница 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Страница 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Страница 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Страница 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Страница 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Страница 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Страница 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Страница 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Страница 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Страница 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Страница 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Страница 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Страница 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Страница 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...

Отзывы: