background image

CNG

 

dispensers

 

TATSUNO

 

EUROPE

 ‐ 

Quick

 

User

 

Guide

 

,

 

revision

 

01,

 

March

 

2022

 

 

 

 

29

 

setting

 

the

 

counter

 

status

 

before

 

switching

 

it

 

off.

 

The

 

information

 

that

 

would

 

appear

 

on

 

the

 

display

 

before

 

the

 

counter

 

was

 

last

 

turned

 

off

 

is

 

displayed.

 

If

 

the

 

counter

 

was

 

operating

 

in

 

manual

 

mode,

 

then

 

it

 

is

 

possible

 

to

 

start

 

pumping

 

immediately

 

after

 

picking

 

up

 

the

 

nozzle.

 

If

 

the

 

counter

 

was

 

operating

 

in

 

automatic

 

mode,

 

it

 

waits

 

for

 

communication

 

with

 

the

 

control

 

computer

 

to

 

be

 

established

 

and,

 

if

 

necessary,

 

for

 

the

 

transaction

 

to

 

be

 

terminated

 

(payment),

 

if

 

it

 

was

 

not

 

terminated

 

regularly

 

before

 

switching

 

off.

 

Now

 

the

 

dispenser

 

is

 

ready

 

for

 

delivery.

 

5.2.1.

 

CNG

 

DISPENSER

 

COMMISSIONING

 

Setting

 

of

 

mass

 

flow

 

meter

 

zero

point

 

All

 

CNG

 

mass

 

flow

 

meters

 

based

 

on

 

the

 

principle

 

of

 

the

 

Coriolis

 

effect

 

are

 

sensitive

 

to

 

the

 

setting

 

of

 

zero

 

(zero

 

flow

 

rate)

 

because

 

with

 

a

 

decreasing

 

flow

 

rate

 

the

 

measuring

 

error

 

increases.

 

The

 

setting

 

of

 

zero

 

must

 

be

 

carried

 

out

 

after

 

every

 

dispenser

 

installation

 

and

 

every

 

meter

 

exchange.

 

The

 

dispenser

 

counter

 

allows

 

carrying

 

out

 

the

 

procedure

 

of

 

setting

 

the

 

zero

point

 

using

 

the

 

service

 

remote

 

controller.

 

The

 

following

 

procedure

 

is

 

intended

 

for

 

authorized

 

service

 

engineers

 

or

 

metrology

 

officials

 

only:

 

 

Close

 

the

 

inlet

 

ball

 

valves

 

at

 

the

 

dispenser

 

inlet

 

and

 

hang

 

the

 

filling

 

nozzles

 

in

 

the

 

dispenser

 

(all

 

filling

 

nozzles

 

must

 

be

 

hung

 

up

 

during

 

zero

 

point

 

setting)

 

 

Break

 

the

 

seal,

 

remove

 

the

 

counter

 

plate

 

cover

 

and

 

set

 

the

 

calibration

 

switch

 

SW1

1

 

to

 

the

 

OFF

 

position.

 

 

Use

 

the

 

PDERT

5S

 

service

 

remote

 

controller

 

to

 

enter

 

the

 

counter

 

service

 

mode

 

(<R>

 

+

 

password).

 

 

Setting

 

parameter

 

P97

 

to

 

1

 

activates

 

the

 

zero

 

point

 

setting

 

function.

 

The

 

counter

 

sends

 

a

 

command

 

to

 

set

 

the

 

zero

 

point

 

to

 

the

 

mass

 

meter

 

and

 

then

 

waits

 

for

 

a

 

response.

 

It

 

then

 

sends

 

information

 

that

 

the

 

zero

 

point

 

was

 

set

 

with

 

the

 

message

 

"DONE"

 

or

 

that

 

it

 

was

 

not

 

set

 

with

 

the

 

message

 

"FAIL".

 

Do

 

not

 

finish

 

the

 

setting

 

until

 

the

 

setting

 

function

 

displays

 

the

 

message

 

"DONE"!

 

NOTICE

 

If

 

the

 

zero

point

 

value

 

is

 

not

 

correct,

 

or

 

the

 

process

 

of

 

zero

point

 

not

 

passed

 

correctly

 

then

 

new

 

filling

 

is

 

not

 

allowed

 

and

 

error

 

message

 

E74

 

is

 

appeared).

 

 

NOTICE

 

The

 

amount

 

display

 

(€)

 

shows

 

the

 

current

 

value

 

of

 

the

 

zero

point.

 

The

 

quantity

 

display

 

(kg)

 

shows

 

the

 

course

 

of

 

the

 

zero

point

 

setting

 

procedure.

 

 

NOTICE

 

In

 

the

 

CNGmass

 

(Endress&Hauser)

 

meter,

 

the

 

course

 

of

 

the

 

procedure

 

is

 

signaled

 

by

 

an

 

increasing

 

number

 

1

 ‐ 

99.

 

After

 

reaching

 

the

 

value

 

99,

 

the

 

process

 

is

 

terminated,

 

and

 

the

 

message

 

"done"

 

is

 

shown.

 

 

 

Exit

 

service

 

mode

 

by

 

pressing

 

<R>

 

on

 

yellow

 

service

 

remote

 

transmitter

 

change

 

position

 

of

 

switch

 

SW

 

1

1

 

to

 

ON

 

(PROTECTED)

 

 

Open

 

ball

 

valves

 

valves

 

at

 

the

 

dispenser

 

inlet.

 

Mass

 

meter

 

configuration

 

When

 

the

 

mass

 

meter

 

is

 

installed

 

into

 

new

 

dispenser

 

or

 

when

 

the

 

mass

 

meter

 

is

 

changed

 

to

 

another

 

one,

 

it

 

must

 

be

 

configured

 

by

 

the

 

calculator

 

TBELTM.

 

This

 

configuration

 

is

 

necessary

 

to

 

perform

 

via

 

parameter

 

P99

 

=

 

4444.

 

Function

 

is

 

enabled

 

only

 

in

 

case

 

when

 

switch

 

SW1

1

 

is

 

in

 

position

 

OFF

 

only

 

(NOT

 

PROTECTED).

 

Switch

 

SW1

1

 

is

 

placed

 

in

 

the

 

centre

 

of

 

the

 

TBELTM

 

processor

 

unit

 

and

 

protected

 

by

 

the

 

sealed

 

metal

 

cover.

 

After

 

start

 

of

 

function

 

P99

 

=

 

4444

 

the

 

counter

 

sends

 

the

 

necessary

 

parameters

 

to

 

the

 

mass

 

meter.

 

 

4

       

 

tbELtM

 

 

1000

 

300.0

 

10.00

 

30.00

 

      

2P

   

30

 

1

 

 

P97

 

Содержание EUROPE

Страница 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Страница 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Страница 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Страница 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Страница 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Страница 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Страница 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Страница 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Страница 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Страница 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Страница 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Страница 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Страница 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Страница 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Страница 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Страница 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Страница 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Страница 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Страница 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Страница 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Страница 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Страница 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Страница 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Страница 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Страница 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Страница 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Страница 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Страница 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Страница 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Страница 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Страница 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Страница 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Страница 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Страница 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Страница 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Страница 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Страница 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Страница 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...

Отзывы: