background image

TATSUNO

 

EUROPE

 

a.s.,

 

www.tatsuno

europe.com

 

 

 

24

be

 

modified

 

in

 

any

 

way

.

 

Parameter

 

Meaning

 

P01

1

 

quantity

 

of

 

gas

 

flown

 

through

 

the

 

hose

 

1

 

in

 

hundredths

 

of

 

kilogram

 

(x

 

0.01kg)

 

P01

2

 

quantity

 

of

 

gas

 

flown

 

through

 

the

 

hose

 

2

 

in

 

hundredths

 

of

 

kilogram

 

(x

 

0.01kg)

 

 

NOTE

 

Number

 

of

 

totalizers

 

of

 

delivery

 

hoses

 

shown

 

in

 

the

 

P01

 

parameter

 

is

 

conditioned

 

by

 

the

 

configuration

 

of

 

the

 

dispenser.

 

 

4.1.6.

 

DAILY

 

QUANTITY

 

TOTALIZERS

 

(P02)

 

Electronic

 

daily

 

quantity

 

totalizers

 

for

 

all

 

dispensing

 

hoses

 

are

 

stored

 

in

 

the

 

electronic

 

counter's

 

memory.

 

They

 

indicate

 

how

 

much

 

fuel

 

has

 

been

 

delivered

 

by

 

the

 

individual

 

dispensing

 

hoses

 

after

 

the

 

last

 

reset

 

(e.g.,

 

after

 

the

 

start

 

of

 

the

 

shift).

 

These

 

totalizers

 

can

 

be

 

reset

 

at

 

any

 

time

 

using

 

parameter

 

P15

 

(see

 

description

 

below).

 

Parameter

 

Meaning

 

P02

1

 

quantity

 

of

 

gas

 

flown

 

through

 

the

 

hose

 

1

 

in

 

hundredths

 

of

 

kilogram

 

(x

 

0.01kg)

 

P02

2

 

quantity

 

of

 

gas

 

flown

 

through

 

the

 

hose

 

2

 

in

 

hundredths

 

of

 

kilogram

 

(x

 

0.01kg)

 

4.1.7.

 

FUEL

 

PRODUCT

 

UNIT

 

PRICES

 

(P03)

 

This

 

feature

 

allows

 

you

 

to

 

view

 

and

 

set

 

current

 

unit

 

prices

 

(i.e.,

 

one

 

kilo

 

of

 

gas)

 

of

 

all

 

fuel

 

products.

 

These

 

fuel

 

unit

 

prices

 

are

 

set

 

on

 

the

 

display

 

at

 

the

 

first

 

lift

 

of

 

the

 

delivery

 

nozzle

 

and

 

reset

 

of

 

the

 

display

 

if

 

the

 

dispenser

 

works

 

in

 

the

 

manual

 

mode

.

 

Setting

 

is

 

made

 

by

 

pressing

 

the

 

<E>

 

key

 

and

 

entering

 

the

 

price

 

in

 

the

 

<PPPP>

 

format

 

and

 

confirming

 

by

 

the

 

<E>

 

key.

 

The

 

decimal

 

point

 

is

 

not

 

entered.

 

E.g.,

 

unit

 

price

 

1.03

 

€/kg

 

is

 

entered

 

as

 

number

 

0103,

 

price

 

34.15

 

CZK/kg

 

as

 

number

 

3415,

 

etc.

 

Parameter

 

Meaning

 

Factory

 

setting

 

P03

1

 

product

 

unit

 

price

 

hose

 

1

 

0.00

 

Euro

 

/

 

kg

 

P03

2

 

product

 

unit

 

price

 

hose

 

2

 

0.00

 

Euro

 

/

 

kg

 

 

NOTE

 

Number

 

of

 

fuel

 

products

 

shown

 

in

 

the

 

P03

 

parameter

 

is

 

conditioned

 

by

 

the

 

configuration

 

of

 

the

 

dispenser.

 

If

 

you

 

change

 

the

 

unit

 

price,

 

such

 

change

 

will

 

be

 

reflected

 

after

 

a

 

subsequent

 

lift

 

of

 

the

 

delivery

 

nozzle.

 

 

NOTICE

 

Values

 

set

 

in

 

the

 

P03

 

parameter

 

are

 

valid

 

in

 

the

 

dispenser

 

manual

 

mode

 

only.

 

If

 

the

 

dispenser

 

is

 

connected

 

to

 

the

 

central

 

control

 

system

 

of

 

the

 

fuel

 

station,

 

then

 

the

 

fuel

 

unit

 

price

 

is

 

set

 

directly

 

by

 

the

 

control

 

system

 

before

 

each

 

delivery.

 

In

 

such

 

case

 

the

 

values

 

of

 

the

 

P03

 

parameter

 

are

 

non

functional.

 

 

 

NOTICE

 

The

 

dispenser

 

does

 

not

 

enable

 

deliveries

 

with

 

a

 

zero

 

value

 

of

 

the

 

unit

 

price.

 

In

 

such

 

case,

 

after

 

lifting

 

the

 

delivery

 

nozzle

 

the

 

dispenser

 

display

 

shows

 

the

 

error

 

message

 

E30

 

and

 

the

 

delivery

 

does

 

not

 

start.

 

4.1.8.

 

CURRENT

 

TIME

 

AND

 

DATE

 

(P04)

 

This

 

function

 

allows

 

to

 

view

 

and

 

set

 

the

 

current

 

time

 

and

 

date.

 

The

 

setting

 

is

 

made

 

by

 

pressing

 

the

 

<E>

 

key

 

by

 

entering

 

the

 

time/date

 

in

 

the

 

correct

 

format

 

and

 

confirming

 

with

 

the

 

<E>

 

key.

 

 
 
 
 

NOTE

 

The

 

time/date

 

information

 

is

 

used

 

by

 

parameters

 

P07

 

and

 

P07

 

to

 

record

 

the

 

exact

 

moment

 

of

 

the

 

fault

 

and

 

end

 

of

 

delivery.

 

The

 

date/time

 

data

 

has

 

only

 

an

 

informative

 

function,

 

it

 

does

 

not

 

affect

 

the

 

process

 

of

 

fuel

 

delivery.

 

 

 

NOTICE

 

The

 

internal

 

clock

 

is

 

reset

 

at

 

least

 

48

 

hours

 

after

 

the

 

power

 

supply

 

off.

 

Time

 

and

 

date

 

values

 

will

 

switch

 

to

 

factory

 

setting

 

and

 

must

 

be

 

set

 

again!

 

Parameter

 

Meaning

 

Factory

 

setting

 

P04

1

 

Time

 

setting,

 

format

 

HHMMSS

 

(i.e.,

 

125600

 

=

 

12:56:00)

 

0:00:00

 

P04

2

 

Date

 

setting,

 

format

 

DDMMYY

 

(i.e.,

 

230821

 

=

 

23.

 

08.

 

2021)

  

1.1.2001

 

time

 

125600

 

P04

1

 

date

 

230821

 

P04

2

 

Содержание EUROPE

Страница 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Страница 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Страница 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Страница 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Страница 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Страница 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Страница 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Страница 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Страница 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Страница 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Страница 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Страница 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Страница 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Страница 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Страница 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Страница 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Страница 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Страница 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Страница 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Страница 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Страница 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Страница 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Страница 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Страница 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Страница 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Страница 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Страница 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Страница 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Страница 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Страница 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Страница 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Страница 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Страница 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Страница 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Страница 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Страница 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Страница 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Страница 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...

Отзывы: