background image

CNG

 

dispensers

 

TATSUNO

 

EUROPE

 ‐ 

Quick

 

User

 

Guide

 

,

 

revision

 

01,

 

March

 

2022

 

 

 

 

5

 

1.1.

 

PERMITTED

 

USE

 

TATSUNO

 

EUROPE

 

dispensers,

 

OCEAN

 

CNG

 

type

 

series,

 

are

 

designed

 

for

 

stationary

 

or

 

mobile

 

placement

 

for

 

refuelling

 

motor

 

vehicles

 

with

 

compressed

 

natural

 

gas

 

(CNG)

 

in

 

a

 

given

 

amount

 

from

 

a

 

gas

 

storage

 

to

 

a

 

tank

 

of

 

a

 

motor

 

vehicles.

 

CAUTION

 

Dispensers

 

are

 

complex

 

devices

 

that

 

must

 

secure

 

a

 

whole

 

range

 

of

 

difficult

 

functions.

 

Therefore,

 

tanks

 

and

 

pipelines

 

must

 

be

 

cleaned

 

and

 

fuel

 

must

 

be

 

checked

 

for

 

cleanliness

 

before

 

commissioning

 

(Filter

 

clogging

 

in

 

a

 

dispenser

 

cannot

 

be

 

considered

 

a

 

reason

 

for

 

warranty

 

repair!).

 

An

 

inspection

 

of

 

wiring

 

and

 

a

 

check

 

of

 

connection

 

correctness

 

must

 

be

 

performed

 

before

 

commissioning

 

to

 

prevent

 

any

 

electric

 

shock

 

injuries

 

and

 

to

 

ensure

 

safety

 

against

 

explosion

 

(fuels

 

are

 

combustibles

 

of

 

class

 

I).

 

 

 

NOTICE

 

Any

 

modification

 

of

 

the

 

dispenser

 

may

 

invalidate

 

the

 

device

 

certification.

 

Refer

 

to

 

certification

 

documents

 

and

 

manufacturer

 

instruction

 

manuals

 

if

 

any

 

modification

 

of

 

the

 

wiring

 

and/or

 

device

 

is

 

considered.

 

Each

 

dispenser

 

is

 

properly

 

tested

 

in

 

the

 

factory

 

in

 

terms

 

of

 

its

 

function,

 

safety,

 

and

 

metrology.

 

The

 

delivery

 

of

 

each

 

dispenser

 

also

 

contains

 

certification

 

documents

 

that

 

must

 

be

 

submitted

 

by

 

the

 

operator

 

on

 

demand.

 

1.2.

 

HEALTH

 

AND

 

SAFETY

 

1.1.1.

 

LIST

 

OF

 

SAFETY

 

FACTORS

 

 

Any

 

odour

 

of

 

CNG

 

(methane)

 

must

 

be

 

immediately

 

reported.

 

 

It

 

is

 

necessary

 

that

 

all

 

work

 

at

 

the

 

fuel

 

station,

 

especially

 

construction

 

and

 

repairs,

 

is

 

performed

 

fill

 

yin

 

compliance

 

with

 

this

 

list.

 

 

It

 

is

 

the

 

obligation

 

of

 

the

 

constructor

 

that

 

all

 

his

 

employees

 

comply

 

with

 

all

 

laws,

 

directives,

 

and

 

other

 

regulations.

 

 

Gas

 

(CNG)

 

may

 

only

 

be

 

stored

 

in

 

tanks

 

and

 

containers

 

compatible

 

with.

 

 

Locations

 

requiring

 

higher

 

carefulness

 

 

Pressure

 

containers,

 

supply

 

pressure

 

pipes

 

and

 

dispensers.

 

 

Any

 

places

 

near

 

dispensers

 

and

 

pressure

 

tanks

 

during

 

filling,

 

especially

 

in

 

still

 

air.

 

 

1

 

meter

 

circuit

 

around

 

the

 

gas

 

pipes.

 

 

The

 

filters.

 

1.1.2.

 

OBLIGATIONS

 

OF

 

EMPLOYEES

 

 

To

 

ensure

 

optimum

 

prevention

 

of

 

injuries,

 

in

 

addition

 

to

 

general

 

rules

 

for

 

employee

 

protection

 

it

 

is

 

necessary

 

to

 

consider

 

also

 

national

 

legislation

 

about

 

employee

 

protection

 

and

 

actively

 

support

 

all

 

measures

 

improving

 

safety

 

standards.

 

 

An

 

employee

 

is

 

obliged

 

to

 

observe

 

all

 

company

 

guidelines

 

about

 

accident

 

prevention

 

except

 

for

 

the

 

cases

 

when

 

these

 

guidelines

 

are

 

assessed

 

as

 

illegitimate.

 

 

Employees

 

must

 

not

 

act

 

according

 

to

 

any

 

instruction

 

that

 

violate

 

safety

 

rules.

 

 

Employees

 

may

 

use

 

designed

 

tools

 

only

 

for

 

their

 

original

 

purposes

 

that

 

are

 

defined

 

by

 

the

 

company

 

itself.

 

 

If

 

an

 

employee

 

detects

 

a

 

tool

 

unsuitable

 

in

 

terms

 

of

 

safety,

 

he/she

 

must

 

immediately

 

remove

 

the

 

defect.

 

If

 

the

 

defect

 

removal

 

is

 

not

 

within

 

the

 

employee`s

 

job

 

content

 

or

 

if

 

an

 

employee

 

does

 

not

 

have

 

enough

 

knowledge

 

for

 

its

 

removal,

 

he/she

 

must

 

immediately

 

inform

 

his/her

 

superordinate.

 

The

 

same

 

applies

 

also

 

to

 

the

 

following:

 

 

Working

 

materials

 

that

 

are

 

not

 

properly

 

packed

 

or

 

correctly

 

described

 

so

 

that

 

they

 

correspond

 

to

 

safety

 

requirements.

 

Содержание EUROPE

Страница 1: ...ensersUserRev01 docx Revision Date revision 01 March 2022 Number of pages 40 including cover Created by Ing Milan Berka TATSUNO EUROPE a s Pra sk 2325 68 678 01 Blansko Czech Republic tel 420 516 4284...

Страница 2: ...01 Blansko Czech Republic Tel 420 516428411 Fax 420 516428410 e mail info tatsuno europe com http www tatsuno europe com Copyright Neither the manual nor any part of it may be reproduced without the e...

Страница 3: ...HE DISPENSER 14 2 6 NAMEPLATES 15 3 INSTALLATION 16 3 1 INSTRUCTIONS FOR OCCUPATIONAL SAFETY 16 3 2 RECEIPT TRANSPORT UNPACKING 16 3 3 DISPENSER LOCATION 17 3 4 MECHANICAL ATTACHMENT OF THE DISPENSER...

Страница 4: ...0 5 9 2018 Basic version of the document Milan Berka Revision 01 31 3 2022 Update of technical data error messages dispenser settings PDEX5 Ocean Tower CNG Milan Berka 1 INTRODUCTORY INFORMATION Symbo...

Страница 5: ...the fuel station especially construction and repairs is performed fill yin compliance with this list It is the obligation of the constructor that all his employees comply with all laws directives and...

Страница 6: ...For unmanned fuel stations breakaway couplings must also be used to reduce the risk in the case of departure after the delivery nozzle has been forgotten in the vehicle tank WARNING Only qualified per...

Страница 7: ...les and checkthecondition of dispensers reservoirs machinery operation gas pressure and keep prescribed operating records in regular intervals Attendant s responsibilities Keep the operated devices in...

Страница 8: ...for private use display only the dispensed fuel quantity in kilograms NOTICE Standard painted versions of TATSUNO EUROPE dispensers are not intended for use in high humidity chemical and saltwater ar...

Страница 9: ...tic valves Two state 24VDC max 1A Data transmission of the entire contents of the display with the number of digits 7 6 5 5 is only possible using the extended communication protocol 8 8 6 2 3 DISPENS...

Страница 10: ...ispenser marking and sorting system In the case of a double sided dispenser the right side of the dispenser is also referred to as side A and the left side is referred to as side B For a one sided lef...

Страница 11: ...40x1 OEL R CNG 1 x 1 1 1 1x30 BMP40x1 OEL R CNG H 1 x 1 1 1 1x70 BMP40x2 OED CNG 2 x 2 2 2 2x30 BMP40x2 OED CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OED CNG H H 2 x 2 2 2 2x70 BMP40x2 OEL R CNG H 1 x 1 2 1 1...

Страница 12: ...1 x 1 1 1 1x30 BMP40x1 OSL R CNG H 1 x 1 1 1 1x70 BMP40x2 OSD CNG 2 x 2 2 2 2x30 BMP40x2 OSD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OSD CNG H H 2 x 2 2 2 2x70 BMP40x2 OSL R CNG H 1 x 1 2 1 1x30 1x70 BMP40...

Страница 13: ...OWL R CNG 1 x 1 1 1 1x30 BMP40x1 OWL R CNG H 1 x 1 1 1 1x70 BMP40x2 OWD CNG 2 x 2 2 2 2x30 BMP40x2 OWD CNG H 2 x 2 2 2 1x30 1x70 BMP40x2 OWD CNG H H 2 x 2 2 2 2x70 BMP40x2 OWL R CNG H 1 x 1 2 1 1x30...

Страница 14: ...sic parts of the WSE dispensing module and its cover Position Device Position Device Position Device 1 CNG mass meter 6 CNG hose filling 11 Nozzle cover stainless without a switch 2 CNG electromagneti...

Страница 15: ...Marking of the dispenser type see section 2 3 OIML certificate Number of the OIML certificate Serial number Serial number of the dispenser seq number year of production Gas temperature range Range of...

Страница 16: ...handling and transport If the transport is ensured by the customer in another way the manufacturer shall ensure professional loading However the manufacturer is not responsible for the method of trans...

Страница 17: ...ce for dispenser installation must be structurally secured so that the possibility of dispenser damage by an incoming car and following medium leakage into atmosphere is avoided as best as possible Th...

Страница 18: ...lling the dispenser at the filling station the following must be taken into account in particular what danger zones the dispenser creates with its operation what danger zones are created by the surrou...

Страница 19: ...counters used in these dispensers are separated from other areas by a type 1 partition according to EN 13617 1 they are in an uncovered design IP54 IP55 and must therefore be located in a non explosiv...

Страница 20: ...the grounding system As a grounding wire you can use a yellow green cable with a section of at least 4 mm2 or a special grounding strap The grounding wire must be connected to a central grounding term...

Страница 21: ...nged using the remote IR infrared controller the service keypad or the pre set keypad buttons located on the dispenser The basic control unit of the dispenser is an electronic counter which is stored...

Страница 22: ...d to set the volume amount pre selection on the dispenser Unlocking the dispenser after delivery If the dispenser is in the manual mode with the blocking after delivery you can unlock the dispenser wi...

Страница 23: ...d service staff who can set a new one After entering the valid access password the display shows the value of the first parameter P00 1 Now it is possible to browse parameters by using the key or by e...

Страница 24: ...er Meaning Factory setting P03 1 product unit price hose 1 0 00 Euro kg P03 2 product unit price hose 2 0 00 Euro kg NOTENumber of fuel products shown in the P03 parameter is conditioned by the config...

Страница 25: ...g error message is displayed 4 1 10 ERROR MESSAGE CODES HISTORY P06 The function is used to display the history of the last 100 error message codes that have occurred and displayed on the dispenser Th...

Страница 26: ...ting 12 0 Automatic mode with remote control The dispenser is remotely controlled by a computer or station controller via a data line It starts fuel delivery only when an authorization command from th...

Страница 27: ...following arrangement of data on the display the first line of the display shows the temperature on the processor unit of the counter intenthsofCelsiusdegrees 26 C Thesecondlineshowsanaverageambientte...

Страница 28: ...ns of all installed technical devices Do not allowpersonswithoutappropriateprofessionalqualificationtotampertheinstalledtechnology includingthegasdevices CAUTION It is forbidden to smoke and use open...

Страница 29: ...service remote controller to enter the counter service mode R password Setting parameter P97 to 1 activates the zero point setting function The counter sends a command to set the zero point to the mas...

Страница 30: ...serious deficiencies he she is entitled to refuse storage tank filling In case of gas leak or danger the attendant shall finish the delivery The operation of the dispenser itself is ensured by the em...

Страница 31: ...tion Immediately inform the operator about each defect failure or abnormality during operation Immediately decommission the device in case of gas leak or danger Keep tidiness and cleanliness and ensur...

Страница 32: ...control deliveries from the fuel station booth The booth contains a control device by which the fuel station attendant releases the dispenser for delivery and collects information about the delivered...

Страница 33: ...down that ensure safe deceleration of fuel flow rate before the target preset value a Example of entering the pre selection in Euros The customer arrives to the dispenser and wants to deliver fuel for...

Страница 34: ...to the counter memory and will be shown after the power supply is connected again see the previous section Now the dispenser is out of order 6 MAINTENANCE AND SERVICE 6 1 MAIN PRINCIPLES OF DISPENSER...

Страница 35: ...nter season when due to the activity of aerosols from chloride agents created from salts used for road maintenance the paint of unprotected body parts may be permanently damaged or inter crystal corro...

Страница 36: ...the circuit breaker for the single phase power supply 230V of the dispenser in the main switchboard of the fuel station If the dispenser is connected to the control computer the dispenser blocking may...

Страница 37: ...munication Controlling computer not connected or communication cable not connected correctly E20 NFAT Power failure during delivery Check the dispenser power supply If the fault persists call an autho...

Страница 38: ...witchboard the valves on the supply line must be fully closed during service work vehicles must be prevented from passing within 5 meters around a fire extinguisher must be available to workers servic...

Страница 39: ...CNG dispensers TATSUNO EUROPE Quick User Guide revision 01 March 2022 39 6 3 3 EU DECLARATION OF CONFORMITY...

Страница 40: ...TATSUNO EUROPE a s www tatsuno europe com 40 NOTES...