24
TASCAM DA-6400/DA-6400dp
4 – Recording
Setting input monitoring for specific
channels
When the
MODE
on the
INPUT MONITOR
screen is set to
Individual
, input monitoring can be turned on/off for
specific channels individually or all at once.
1. Open the
INPUT MONITOR
operation procedures” on page 16.)
2. On the
INPUT MONITOR
screen, set the input
monitoring mode to
Individual
.
Underneath the
MODE
item, the
RANGE SELECT
item
appears.
3. Press the
MULTI JOG
dial to confirm and move the cursor to
the next item.
Use the
.
/
/
[MARK
.
/
/
]
buttons to move the
cursor.
When the cursor is at ON or OFF, press the
MULTI JOG
dial to
open a confirmation pop-up message.
When the confirmation message is open, press the
MULTI
JOG
dial to set all channels at once.
Setting the first channel to be included when selecting a range
of channels at once
Options:
CH01
–
CH63
: First channel included when selecting a
range of channels at once
CH02
–
CH64
: Last channel included when selecting a
range of channels at once
OFF
/
ON
: Input monitoring status for range of channels
selected at once
4. By moving the cursor to the input monitoring indicator area,
you can set input monitoring for individual channels.
Press the
MULTI JOG
dial to enable/disable
monitoring
for
the channel where the cursor is.
NOTE
You can also turn the
MULTI JOG
dial to select a channel.
Turn the
MULTI JOG
dial while pressing and holding the
SHIFT
button to move the cursor by 4 channels at a time.
Making recording channel settings
1. Select the
REC FUNCTION
item on the
REC FILE
FORMAT
page to open the
REC FUNCTION
screen. (See
“Menu operation procedures” on page 16.)
2. Set the recording function mode.
Options
ALL ON
(default): Recording is enabled for all channels
ALL OFF
: Recording is disabled for all channels
Individual
: Allow recording to be enabled/
disabled for specific channels individually or all at once
3. Confirm the setting and return to the Menu Screen.
Setting the record function for specific
channels
When the
MODE
on the
REC FUNCTION
screen is set to
Individual
, recording can be enabled/disabled for specific
channels individually or all at once.
1. Open the
REC FUNCTION
2. Set the recording function mode on the
REC FUNCTION
screen to
Individual
.
Underneath the
MODE
item, the
RANGE SELECT
item
appears.
3. Press the
MULTI JOG
dial to confirm and move the cursor to
the next item.
Use the
.
/
/
[MARK
.
/
/
]
buttons to move the
cursor.
When the cursor is at ON or OFF, press the
MULTI JOG
dial to
open a confirmation pop-up message.
When the confirmation message is open, press the
MULTI
JOG
dial to set all channels at once.
Setting the first channel to be included when selecting all
channels at once