![T&D RTR-5 US Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/tandd/rtr-5-us/rtr-5-us_user-manual_3076494042.webp)
37
4
.
Upon completion the [Registration Contents] will be displayed and by
clicking [Close] the registration will be finished and the window closed.
Note
- By clicking on a Group Name, the Frequency Channel for that group, as well as,
the Remote Unit Name(s) and Number(s) in that group will be displayed.
[Group Name]
- Group Names can be entered with up to
8
letters.
- You can also select an already registered group name and make slight
changes to make a new name.
- If you are using a multiple number of Data Collectors (RTR-
57
C/
57
U) and
register units using the same Group name, communication may occur with a
Remote Unit registered to a different Data Collector (RTR-
57
C/
57
U).
Hence, if you are using a multiple number of Data Collectors, please register
units making sure to use different Group names for each Data Collector.
[Remote Unit Name]
- Remote Names can be entered with up to
8
letters.
- You can also select an already registered remote name and make slight
changes to create a new name.
[Communication Frequency Channel]
- By clicking the [Set] check box you can select a channel number.
- One Frequency Channel (
0
to
21
) can be set for each Group.
CH
Frequency(MHz)
CH
Frequency(MHz)
CH
Frequency(MHz)
CH
Frequency(MHz)
0
902
.
28072
6
909
.
358608
12
916
.
436496
18
923
.
514384
1
903
.
460368
7
910
.
538256
13
917
.
616144
19
924
.
694032
2
904
.
640016
8
911
.
717904
14
918
.
795792
20
925
.
87368
3
905
.
819664
9
912
.
897552
15
919
.
97544
21
927
.
053328
4
906
.
999312
10
914
.
0772
16
921
.
155088
5
908
.
17896
11
915
.
256848
17
922
.
334736
Note
- The default frequency channel setting for Group
1
is '
0
'
- If no settings are chosen, an unused frequency channel will be automatically
assigned.
- A frequency channel setting can only be made when registering a new group.
- Once a channel has been set for a group it cannot be changed.
- The specified frequency channel will be used for all communication with remote
units in that group. If another RTR-
57
C/
57
U is using the same channel in the same
area, communication may become unstable.