CONTROLLER
INFORMATION
PROGRAMMABLE FACTORS - OPERATOR LEVEL
Parameter
¼ Turn
Static
Range
Units
Description
Operator Menu
Contrast
6
6
0-12
-
Set Screen Contrast
Film Break
Off
Off
On/Off
-
Toggles Film Break sensing on/off
AutoLoad
Off
-
On/Off
-
Activate loading via autoloading sensor
Auto Off-load
Off
Off
On/Off
-
Unloading Sequence starts automatically once wrapping has finished
Autostart Wrap
Off
On
On/Off
-
Wrapping sequence starts once autostart pressed (Key R6) or after
loading if autostart wrap set to ON
Remote Type
IR
IR
IR/RF/RF learn
-
Select Type of remote control to be used
Load Up
6
-
0 - 9.9
Seconds
Load arm Lift Up duration
Load down pause
0
-
0 - 9.9
Seconds
Pause Duration before load arm lowers
Tip Up
2
2
0 - 9.9
Seconds
Tip duration after tip sensor lost
Tip up to down
0.3
0.3
0 - 9.9
Seconds
Pause duration before Table lowers
Tip Down
3.5
3.5
0 - 9.9
Seconds
Duration to lower table
Fast Last Rev
1
1
0 - 9.99
Seconds
Duration of the last revolution in fast speed
Load down time
0.2
-
0 - 9.9
Seconds
Duration load arm drops after seen Input 3 (Load arm Sensor)
¼ Turn
On
Off
On/Off
-
Turn Table ¼ turn to loading position after offloading cycle complete
Language
English
English
-
-
The default settings for the machine are developed by Tanco for optimal operation of the
machine. However, the operator can change certain parameters in the ‘Operator Setup’ menu
to take account of operational conditions.
A100 EH Operator’s Manual
32 //
49