Print 80 - 9F Hex
This parameter defines whether locations 80 through 9F Hex are to be treated
as control characters or printable characters. The function of the control
characters in this area depends on the emulation. The selections are ON
(printable characters) or OFF (control characters). The default value depends
on the emulation.
Ignore Char
This parameter allows you to select a character that will be ignored in the
incoming data stream. This parameter functions in all emulations and
non-downloadable print modes. It does not function in plot mode, font
download, or VFU download. Selections are 0-255, referring to the decimal
value of any 8-bit character, or OFF. Default is OFF.
Sub Char From
This parameter allows you to select a character that will be replaced by the
character designated by the Sub Char To parameter. This parameter
functions in all emulations and non-downloadable print modes. It does not
function in plot mode, font download, or VFU download. Default is OFF.
Sub Char To
This parameter allows you to select the character that will replace the
character designated by the Sub Char From Parameter. This parameter
functions in all emulations and non-downloadable print modes. It does not
function in plot mode, font download, or VFU download. Default is OFF.
PTX SFCC
Defines the Special Function Control Character used by the Printronix P5000
emulation. The decimal value of the ASCII character code is entered. The
default value is 1 (SOH).
PTX ALS
Defines the single line Alternate Line Spacing used by the ACK (Hex 06)
command in the Printronix P5000 emulation. The possible selections are 8 or
10.3 which define the line density. The default value is 8.
NOTE:
The PTX SFCC and PTX ALS options will only appear if the Printronix
P5000 emulation is selected with the Ser/Par Emul control panel
option.
TOF Control
(Available when Genicom ANSI emulation is selected)
When a new form is defined, the top-of-form position is left unchanged if this
parameter is set to Enable (the default). When a new form is defined, and this
parameter is set to Disable, the top-of-form position is reset to the top margin
of that form.
Содержание 6800 Series
Страница 1: ...TallyGenicom 6800 Series Printers Administrator s Manual ...
Страница 3: ...Administrator s Manual TallyGenicom 6800 Series Printers ...
Страница 10: ...Table of Contents ...
Страница 18: ...18 Chapter 1 Contact Information ...
Страница 52: ...52 Chapter 3 Integrated Print Management System ...
Страница 192: ...192 Appendix A Printing Speed ...
Страница 194: ...194 Appendix B ASCII Character Set ...
Страница 200: ...200 Appendix C Stacker Operation ...
Страница 231: ...231 ...
Страница 256: ...256 ...
Страница 257: ......
Страница 258: ...256667 001C 256667 001 ...