Frame back limit over
Frame back reached the limit.
Do not return the frame any further.
2BE
Incorrect function code segment
Functions with start/end are not registered in
a pair of start and end.
Modify the design so that the start and end codes form
a pair, using the dedicated design creation software or
an optional DG product.
2C7
Password requested
Input the password.
Contact your sales dealer.
2C9
Time setting error
Tap [RESET].
2CA
Power OFF/ON incomplete
Turn off the power, wait at least 5 seconds or more,
then turn it back on.
2E3
Power failure during operation
Power supply failed during operation.
Contact your sales dealer.
311
Encoder A signal error
Encoder A signal does not vary.
312
Encoder Z signal error
Encoder Z signal does not vary.
Tap [RESET].
If the issue cannot be resolved, contact your sales
dealer.
316
Main shaft motor error
Main shaft motor or Motor driver is irregular.
Turn off the power, wait at least 5 seconds or more,
then turn it back on.
If the issue cannot be resolved, contact your sales
dealer.
321
Frame driver irregular signal
Frame driver irregular signal, detected.
322
X-Driver irregular signal
X-axis driver irregular signal, detected.
323
Y-Driver irregular signal
Y-axis Driver irregular signal, detected.
32C
X-axis frame travel incomplete
X-axis frame travel is incomplete.
32D
Y-axis frame travel incomplete
Y-axis frame travel is incomplete.
32E
X-axis origin search incomplete
X-axis origin search is incomplete in time.
Contact your sales dealer.
32F
Y-axis origin search incomplete
Y-axis origin search is incomplete in time.
354
Motor overcurrent
Sequin, Zigzag cord
Carry out the procedure below.
• Turn off the power, wait at least 5 seconds or more,
then turn it back on.
• Lower the rotation speed.
If the issue cannot be resolved, contact your sales
dealer.
362
Jump motor overcurrent
382
Color change error in 1 sec.
The needle position signal status during color
change does not change for 1 second and
more.
Contact your sales dealer.
383
Needle Position Error
There was no needle position signal during
rotation of the main shaft.
3A6
Movable Knife Open
ATH Knife retractable position has become
nonuniform.
Code
Message