Back to Table of Contents
37
Mode” enter “13” followed by a eight digit number that will serve as a new master Code.
Note: It is recommended to change master code when setting up.
Erase All
After entering the “Programming Mode,” enter “6” and then eight digits Master code.
Warning! Cards can not be restored after they are erased!
1.2.7 Indicators definitions
After entering setup mode:
Input Operation Mode
Code 30 -->0 = Door open request button
As a result the door will open and the output = bypass
1 = Door sensor
As a result the output = alarm will be activated (led/buzzer)
Sensor type
Code 31-->0 = The sensor will function as Normally Open.
1 = The sensor will function as Normally Closed.
Alarm mode
Code 51--> 0 = Latch. The alarm does not go off unless it is turned off
manually.
1 = Pulse. The alarm goes off after the defined time-out.
Alarm pulse activating time
Note: Relevant when alarm is in pulse mode.
Code 52--> 0000-9999 seconds (always key-in time in 4 digits format)
Sensor door activating time