background image

 -                                                                                                                                            

2

All rights reserved. Reproduction or use, without express permission of editorial or pictorial content, 

in any manner is prohibited. No patent liability is assumed with respect to the use of the information 

contained herein. While every precaution has been taken in the preparation of this manual, Synel 

Industries Ltd. assumes no responsibility for errors or omissions. Neither is any liability assumed for 

damages resulting from the use of the information contained herein.

DCM and SY are trademarks of Synel Industries Ltd.

All trade names referenced herein are either trademarks or registered trademarks of their respective 

companies

Содержание PrintX-FPR

Страница 1: ...1 Manual 7 12 09 Catalog no 650460 Document no FPR PRX 222 01 PRX 40 B Terminal PrintX FPR FingerPrint Reader STAND ALONE TERMINALS Product Manual...

Страница 2: ...herein While every precaution has been taken in the preparation of this manual Synel Industries Ltd assumes no responsibility for errors or omissions Neither is any liability assumed for damages resu...

Страница 3: ...7 1PRX 40 B Connection Wires 17 Jumpers 20 8 1PRX 40 B 20 Setting up the Standalone unit 21 9 1To use Proximity Card and Fingerprint mode 21 9 2Setting Proximity Card parameters 21 9 3Entering Proximi...

Страница 4: ...stics 26 Fingerprint Best use Guidelines 27 Troubleshooting 28 Appendices Detailed instructions for Standalone Set up 30 1 1Access cards configuration Set up codes 30 1 2Access cards configuration 34...

Страница 5: ...et up 8 digit code the default number is 12345678 maximizing security In stand alone mode these units grant secure access for approximately 285 card holders stored in an authorized list within the ter...

Страница 6: ...is identified by wither a card or by pin number on the key board and then verifies their identity with by fingerprint Verification can be done in the following ways Swipe card Fingerprint Pin number F...

Страница 7: ...tand alone mode when the device functions as a controller this unit has additional circuitry for storing card holder data PRX 40 B PrintX FPR LED Operation Status Indicator LED Operation Status Indica...

Страница 8: ...Dimensions 15 5 x 7 x 6 1 cm Weight 350 gr Operating temperature 10 to 50 C PrintX FPR Dimensions 15 5 x 7 x 6 1 cm Weight 350 gr Operating temperature 10 to 50 C 3 1 Electrical characteristics Output...

Страница 9: ...R unit 1x PRX 40 B unit A mounting set that includes 2 screws for mounting the mounting panel 2 screw for securing the unit to mounting panel Wall anchors 4 Brick 4 Plaster 1x RJ 11 Connection box wit...

Страница 10: ...etc Maintain at least a one meter distance from computer displays Keep the cable by at least 30 cm away from any other cable Use a power adaptor dedicated to the proximity unit Make sure the adapter...

Страница 11: ...4 7 Place the reader so that the user will be fully facing it when swiping the badge since this is the best swiping position Caution The terminal contains computer components Thus it should not be mou...

Страница 12: ...mplate to the wall and mark the places to drill holes for the screws and cables 3 Drill the holes for the connection cable and screws with 6mm drill bit 4 Inset the screw anchors for either plaster or...

Страница 13: ...Back to Table of Contents 13 6 Slide the unit downward onto to the mounting panel The hinges at the side of the panel 1 should slide into the track of the mounting panel 2 1 2...

Страница 14: ...Back to Table of Contents 14 7 Once the unit is in place you can screw the security screw connecting between the panel and the unit at the top of the unit and panel...

Страница 15: ...Back to Table of Contents 15 7 Connecting the Cables PRX 40B Communication Box...

Страница 16: ...Back to Table of Contents 16 Print X FPR Communication Box...

Страница 17: ...hite 3 P2 9 GND Brown White 3 P2 3 Host Rx Orange 2 P2 2 Host Tx Green 4 From Name Color RJ45 Box2 P1 1 Clock D1 Green 6 P1 2 Clock D0 Blue 7 P1 4 5Vdc Red 3 P1 5 GND Black 4 LED1 2 C Anode Black 3 LE...

Страница 18: ...Back to Table of Contents 18 Wire connection diagram 11 Bell 1 Pink 12 Bell 2 Light green 13 optional as needed Light blue 14 optional as needed Brown White or Brown Black...

Страница 19: ...Back to Table of Contents 19 PRX 40 B Wire connection diagram...

Страница 20: ...JP11 TH PSEN Programming must be closed when programming the master CPU Open JP12 SMD Tamper switch enabled 1 2 closed Tamper switch disabled 2 3 closed 2 3 closed JP20 T H Closed Stand alone Open Onl...

Страница 21: ...rt the relevant set up code see next page Follow the task below for specific instruction of the tasks 9 1 To use Proximity Card and Fingerprint mode Step 1 Press 1 key and 2 key 3 times simultaneously...

Страница 22: ...roximity Cards and Fingerprints to the unit Step 1 Press 1 key and 2 key 3 times simultaneously Step 2 Key in Master code 8 digits Step 3 Key in code 20 Step 4 Bring card to be read by unit Step 5 Whe...

Страница 23: ...n identify mode the user places a finger and if the fingerprint is in the system the user is allowed to enter In verify mode the user is let in only of both card or pin code and fingerprint match what...

Страница 24: ...that number Identification The identification mode does not require a card code combination Up to 9090 fingerprint templates are stored in the terminal s memory When an employee places a finger on th...

Страница 25: ...eft side Fingerprint LED Left side Green Allowed card Successful operation Red Flashing x3 Wrong card Unidentified Wrong fingerprint Orange Non flashing Waiting for finger Flashing x1 per second Waiti...

Страница 26: ...cables The cable should not be installed near EMI factors such as Motors generators alternators and transformers Air conditioners elevators Radio television transmitters signal generators and internal...

Страница 27: ...rder to safely discharge any static electricity on your skin or clothing Place the fingerprint sensor close to a heating source such as a radiator or hot plate Spill any liquids on the sensor with the...

Страница 28: ...her You can have either an Optic or TC Capacity FPU If these conditions are met contact technical support to install Unifinger and change the baudrate Question The controller is not enrolling the fing...

Страница 29: ...finger on the ridge lock and lower your finger onto the sensor surface make sure all other fingers are held straight to avoid creating an angle between the enrolled finger and the sensor surface incor...

Страница 30: ...21 1 1 Access cards configuration Set up codes Name Code Parameter Comments Default Work mode 8 0 1 Stand alone Online From version 3 04 Until now this was done in jumper JP20 Control Door 0 Enter Ma...

Страница 31: ...e 13 00000000 99999999 8 digit code Communicati on ID 14 1 32 Defines terminal ID 01 New global code 15 4 digit new code 9999 Insert card using card 20 In Operation Mode 4 1 Swipe card 2 Insert pin co...

Страница 32: ...als that have one Mode 6 only with PRintX Delete card using keyboard 23 Enter Card number Insert card by Index 24 Card index 4 digits from 0000 0300 Highest possible index depends on card length code...

Страница 33: ...ion 3 04 Duress code enable disable 50 0 1 Disable Enable Activating alarm and relay output Alarm mode 51 0 1 Latch LED is on Pulse LED is off 1 LED is off depending on pulse time code 52 Alarm pulse...

Страница 34: ...card number Using Card Swiping the card By Index Enables deleting an employee without a card 1 2 2 Using the Keyboard Build list After entering set up mode key in code 22 key in card number to list Up...

Страница 35: ...eration mode no 4 card and pin code the user must swipe the card and then key in the code a 4 digit code Delete list After entering set up mode key in code 21 delete card by card and swipe all irrelev...

Страница 36: ...ders Card and PIN Code Control is performed by Card and a personal four digit code This mode is the most secure 4 digit code used by each card holder 1 2 6 General definitions Open Door Access can be...

Страница 37: ...ation Mode Code 30 0 Door open request button As a result the door will open and the output bypass 1 Door sensor As a result the output alarm will be activated led buzzer Sensor type Code 31 0 The sen...

Страница 38: ...he door simultaneously Define Duress code Code 53 0000 9999 Enables defining what will be the duress code Card parameters Refer to how the proximity track will be read Reset alarm In set up mode after...

Страница 39: ...he combinations that can be used Please ask your Synel contact for additional information about these options PRX 40 B and External magnetic reader PRX 40 B and Push button Sensor PRX 40 B and FPR PRX...

Отзывы: