Back to Table of Contents
30
Appendix 1 -Detailed instructions for Standalone Set-up
The following section includes all of the configuration codes that can be used to set-up the standalone
unit. For detailed instructions about the basic settings for the unit, refer to “Setting-up the
Standalone unit” on page 21.
1.1
Access cards configuration (Set-up codes)
Name
Code
Parameter
Comments
Default
Work mode
8
0 -
1 -
Stand alone
Online
From version 3.04
Until now this was
done in jumper
JP20.
Control Door 0
Enter Master code
and
press 0.
Reset alarm 4
When the alarm is in latch
(turned ON)
Check ID
Address
7
Long buzzer - tens
Short buzzer -
unique
Door opening
time
10
000-255
In 1/10 seconds
step (0 to 25.5 sec.)
3 sec.
Card
reading/
check
parameters
11
1,2- Start position (01-37)
3,4- Length (01-06)
5,6- Total Characters
01
16
00