Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
116
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
This command sets the SSM bit to position 4 in the E1 input string on Input 1.
Autonomous Message
TP-SSU 03-10-24 11:05:18
A 1187 REPT EVT
“INP1,T1:NA,SSMBIT,NSA,03-10-24 11-05-18:\"E1 SSM BIT HAS
CHANGED,4\””
;
Enabling CRC4
Use the ED-SYNC command to enable or disable the use of CRC4 on E1 inputs.
ED-SYNC:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-SYNC::INP1:TS1000::CRCENA=ENABLE;
Normal Response
TP-SSU 03-10-24 11:06:57
A 1188 REPT EVT
“INP1,T1:NA,CRCENA,NSA,03-10-24 11-06-57:\"INPUT CRC HAS
CHANGED,ENABLE\””
;
Using Performance Monitoring
You can set thresholds for alarms and for qualifying inputs using MTIE and FFOFF
data. For more information on performance monitoring, see
Performance
Monitoring
, on page 24.
Setting MTIE and FFOFF Thresholds
Use the SET-TH command to set the alarm thresholds for each input and each
MTIE window.
SET-TH:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
<value>
Description
Default value
INPp
p = 1 | 2
CRCENA
ENABLE |
DISABLE
Provisions the use of
CRC4 on E1 inputs
DISABLE
Содержание EDGE CLOCK 1000
Страница 1: ...TimeProvider 1000 and 1100 Edge Clock User s Guide Revision G April 2008 Part Number 097 58001 02 ...
Страница 10: ...Table of Contents 10 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 154: ...Chapter 5 Testing the TimeProvider Test Record 154 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 224: ...Index Y Y 224 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...