Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
172
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
FRMTYPE
Indicates the type of
input framing or the
input frequency. Sets
the input framing type
T1
Output = 2M
1.544M – 1.544 MHz
2M – 2048 kHz
6.312M – 6.312 MHz
CAS – CAS Input
CCS – CCS Input
ESF – Extended SuperFrame
input
CC – Composite Clock input
ISOLATED_1 – Generates an
isolated one test pattern for
T1 outputs
JCC – Japan Composite Clock
JCC4 – Japan Composite
Clock with 400 Hz
OUTSTATE
The specified output
state has changed
T1
DISABLE
ENABLE – The output
generates the defined signal
type
DISABLE – Disables the
output and clears all active
alarms associated with the
input
RQLEVEL
The received quality
level on the specified
input has changed
T1
n/a
Displays the prior quality level
followed by the new quality
level
SYS Events
CLRDELAY
Time, in seconds,
before a faulted signal
indicates it is valid as a
system reference
EQPT
5 s
0 to 1000 s
ELEVTIME
Indicates that Alarm
elevation time (1440
min.) is enabled or
disabled
EQPT
DISABLE
ENABLE | DISABLE
FACTORY
Indicates that the unit
has been reset to
Factory default. All
modules installed in
the system are reset
EQPT
n/a
n/a
FLTDELAY
Time, in seconds,
before faulted signal
indicates it is not valid
as a system reference
EQPT
10 s
1 to 15 s
Table 6-5. Event Codes (Continued)
Event ID
Keyword
Description
AID
TYPE
Default Value/
Keyword
Description of Values
Содержание EDGE CLOCK 1000
Страница 1: ...TimeProvider 1000 and 1100 Edge Clock User s Guide Revision G April 2008 Part Number 097 58001 02 ...
Страница 10: ...Table of Contents 10 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 154: ...Chapter 5 Testing the TimeProvider Test Record 154 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 224: ...Index Y Y 224 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...