Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
132
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Response Format
<cr><lf><lf>
sid date time<cr><lf>
M
ctag COMPLD<cr><lf>
“<aid>:event id,alarm level”<cr><lf>
“<aid>:event id,alarm level”<cr><lf>
.
.
“<aid>:event id,alarm level”<cr><lf>
;
Sample Command
RTRV-ATTR::SYS:TS1000;
This command causes the TimeProvider to return the alarm levels associated with
all system-level alarms.
Normal Response
TP-SSU 03-10-24 11:21:20
M
TS1000 COMPLD
"SYS:IOC1EQPT,NA"
"SYS:IOC2EQPT,NA"
"SYS:PWRA,MJ"
"SYS:PWRB,MJ"
"SYS:EXTALM1,MJ"
"SYS:EXTALM2,CR"
"SYS:EXPFAIL,MJ"
;
Retrieving Current Alarms
You can display the current active alarms using the RTRV-ALM command.
RTRV-ALM:[<tid>]:<aid>:[<ctag>];
Field
Description
<aid>
The aid specified in the command
event id
The identifier of the alarm whose level is displayed
alarm level
The value indicates the alarm level that is generated by an alarm
event:
NR = Not Reported
NA = A non-alarm event
MN = Minor alarm
MJ = Major alarm
CR = Critical alarm
Содержание EDGE CLOCK 1000
Страница 1: ...TimeProvider 1000 and 1100 Edge Clock User s Guide Revision G April 2008 Part Number 097 58001 02 ...
Страница 10: ...Table of Contents 10 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 154: ...Chapter 5 Testing the TimeProvider Test Record 154 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...