Chapter 4 Provisioning the TimeProvider
Provisioning Retimer Parameters
120
TimeProvider User’s Guide
097-58001-02 Revision G – April 2008
Sample Command
ED-SYNC::OUTA:TS1000::FRMTYPE=CAS;
This command provisions output group A to an E1, CAS framing format.
Autonomous Message
TP-SSU 03-10-24 11:11:18
A 1190 REPT EVT
“OUTA,EQPT:NA,FRMTYPE,NSA,03-10-24 11-11-18:\"OUTPUT
FRAMING TYPE HAS CHANGED,CAS\””
;
Provisioning Retimer Parameters
You use several TL1 commands to provision the E1 and T1 Retimers available for
the TimeProvider. The ED-EQPT command with the RTMSTATE keyword allows
you to enable and disable Retimer modules and individual ports; the SLIPCLR
keyword allows you to clear a Slip alarm. The ED-SYNC command with the
RTMLBO keyword allows you to set the line build-out length; the FREEFLT and
HOLDFLT keywords allow you to enable or disable the cut-through mode when the
clock enters Free-run or Holdover mode.
Enabling and Disabling the Retimers
Use the ED-EQPT command to enable or disable the specified Retimer group.
Individual channels cannot be enabled or disabled.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
Sample Command
ED-EQPT::RTMA:TS1000::RTMSTATE=DISABLE;
This command disables the Retimer in group A and turns off both ports.
<aid>
<keyword>
<value>
Description
Default value
RTMg
g = A | B | C | D
RTMSTATE
ENABLE
Enable the specified
Retimer group
ENABLE
DISABLE
Disable the specified
Retimer group
Содержание EDGE CLOCK 1000
Страница 1: ...TimeProvider 1000 and 1100 Edge Clock User s Guide Revision G April 2008 Part Number 097 58001 02 ...
Страница 10: ...Table of Contents 10 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 154: ...Chapter 5 Testing the TimeProvider Test Record 154 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 224: ...Index Y Y 224 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...