097-58001-02 Revision G – April 2008
TimeProvider User’s Guide 129
Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
<aid> = INP1 or INP2
INPDISQ
Specified input has
been disqualified or
qualified as a possible
system reference.
MN | MJ |
CR
FLT
DELAY
Yes
MN
MN
INPAIS
The specified input is
receiving an Alarm
Indication Signal.
1
MN | MJ |
CR
IMMED
No
MN
MN
INPLOS
The specified input has
Loss of Signal.
1
MN | MJ |
CR
IMMED
No
MN
MN
INPOOF
The specified input is
receiving an Out of
Frame signal.
1
MN | MJ |
CR
IMMED
No
MN
MN
INPFRQ
Specified input port’s
calculated received
frequency exceeds the
pull-in range of the
LO.This alarm condition
disqualifies the input as
a possible reference.
2
NR | NA |
MN | MJ |
CR
IMMED
No
MN
NR
INPPHASE
Specified input port’s
phase measurement
exceeds usable value.
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
INPQL
The received SSM is of
lesser quality than the
provisioned QLEVEL for
a specified input. This
alarm occurs when you
provision the input’s
QLEVEL below the
quality level of the LO.
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
EXDSC
Input has had excessive
discontinuities, indicated
by more than 3 signal
faults (OOF, BPV, CRC,
or AIS) within a 5-minute
window. The alarm
clears when the 5-
minute window contains
less than 3 signal faults.
NR | NA |
MN | MJ |
CR
IMMED
No
MN
MN
Table 4-3. Alarm Conditions and Defaults (Continued)
Alarm ID
Description of Alarm
Condition
Possible
Alarm
Levels
Error
Delay
Default
Error
Delay
Editable?
Default Level
SSU
Mode
SUB
Mode
Содержание EDGE CLOCK 1000
Страница 1: ...TimeProvider 1000 and 1100 Edge Clock User s Guide Revision G April 2008 Part Number 097 58001 02 ...
Страница 10: ...Table of Contents 10 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 154: ...Chapter 5 Testing the TimeProvider Test Record 154 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...
Страница 224: ...Index Y Y 224 TimeProvider User s Guide 097 58001 02 Revision G April 2008 ...