ATS-6511A/B/C Users Guide
94
--mask Set the netmask of the system to NETMASK
--broadcast Set the broadcast of the system BROADCAST
--gateway Set the default router for the system to ROUTER
Command Example:
ATS-6511> network_config --mode static --ip 192.168.1.50 --mask 255.255.255.0 --broadcast
192.168.1.255 --gateway 192.168.1.1
Note:
These network settings will take effect immediately. Users should see “<working>”
with a series of periods on the screen. Once the new settings take effect the connection will
time out and drop. Users will need to reconnect to the system using the newly assigned
static IP Address. These settings are also stored on the system automatically and the
system will start up with these settings each time it is rebooted or power cycled.
Query:
ATS-6511>network
[broadcast] 192.168.1.255
[default_gateway] 192.168.1.1
[ip] 192.168.1.50
[mode] static
[netmask] 255.255.255.0
See also:
network, frontpanel_button, settings, status
PPS:
Description:
Select PPS output type.
The 4394A module is capable of producing 1 PPS or DC IRIG signals. It may be
reprogrammed to produce variations of each of these signals on any of the four output
ports. The default settings for pps outputs are:
Ports 1 and 2: pulse, period = 1, width = 1e-4.
In order to configure a specific output port the port address must be given. To identify the
port address use the slot number and port number of the desired port.
Slot Numbering when looking at the rear panel:
[Slot 1] [Slot 3] [Slot 5]
[Slot 2] [Slot 4] [Slot 6]
Port Numbering when looking at the 4394A outputs:
[1] [2] [3] [4]
Configuring a port to generate pulses (e.g. 1 PPS) is accomplished using the pps command.
Pulse outputs can only be generated on the 4394A output module. Multiple pulse rates and
pulse widths can be generated. The period of the pulses is specified in seconds and has a
maximum value of 1 second (1 PPS) and a minimum value of 1e-7 seconds (10Mpps). The