10
Turn on the computer and press Ctrl+P during initial startup (POST) to enter
the Management Engine BIOS Extension (MEBx).
The Ctrl+P shortcut can vary between OEM-provided BIOSs. Refer to the
manufacturer’s documentation for accessing the ME BIOS sub-menu.
The default MEBx password for the computers in the factory-default state is
"admin". The first time you log on to the MEBx, you must change the default
password.
The new passwords must be a strong password.
See
“About passwords used with Intel AMT”
on page 177.
Use the new password from the print-out you made.
11
Enable Intel AMT, if it is not already enabled.
Exiting the MEBx and restarting the computer might be required for the
additional Intel AMT configuration options to appear in the MEBx.
12
If you have the Intel AMT already enabled, before you make any further
changes, select Un-Provision > Full Unprovision in the MEBx to reset all
Intel AMT settings to their defaults. This removes any settings that can fail
the setup and configuration process. We recommend you doing so even if
this is the first time you accessed the MEBx.
13
Set the Provision Mode to Enterprise, if it is not already set.
14
Modify the Provisioning Server settings. Type the IP of the configuration
server and SCS port (the port that Intel SCS is listening to for Hello messages).
By default, the port is 9971.
To view the port, in the Symantec Management Console, click Settings > All
Settings > Remote Management > Out of Band Management > Configuration
Service Settings > General.
15
Type a PID-PPS pair from the print-out you made.
16
Mark the key pair on the paper as used. Each PID-PPS pair can only be used
once.
17
Configure additional parameters, if necessary.
18
Exit the MEBx.
Setting up and configuring initialized Intel AMT computers
The Intel AMT computers that you initialized are sending configuration requests
to the ProvisionServer host name and are ready for setup and configuration.
See
“About Intel AMT initialization”
on page 58.
Configuring Intel AMT computers for out-of-band management
Configuring Intel AMT computers for out-of-band management
82
Содержание ALTIRIS OUT OF BAND MANAGEMENT COMPONENT 7.0 SP3 - V1.0
Страница 1: ...Altiris Out of Band Management Component from Symantec Implementation Guide Version 7 0 SP3 MR1 ...
Страница 6: ......
Страница 30: ...Introducing Out of Band Management Component Where to get more information 30 ...
Страница 48: ...Installing Out of Band Management Component Uninstalling Out of Band Management Component 48 ...
Страница 110: ...Configuring TLS Configuring TLS with mutual authentication 110 ...
Страница 176: ...Troubleshooting Out of Band Management Component Troubleshooting OOB site server installation 176 ...