Table 10-12
Options on the
Power policy
tab
Description
Option
This parameter defines the highest power state at which Intel AMT
will operate while the device is connected to AC power. Note that
this includes operation in higher power states. For example, if the
platform is in S3 and this parameter is set to Host is ON (S0), the
Intel AMT device will not operate until the platform returns to S0.
Default: Intel AMT is always on (S0-S5).
Intel AMT is ON in
the following host
sleep states
Once the Intel AMT device wakes up and the host system is not
turned on, this parameter determines the minimum time (in
minutes) that the Intel AMT device remains operable when there
is no activity. The device returns to a sleep state after the idle
timeout period. The timeout timer is restarted whenever the device
is serving requests. If the value of the parameter is zero (the default
value), the device will remain on when there is no activity. For
example, the AMT is ON parameter is set to Host is ON (S0) or in
Standby (S3). When the platform transitions to S3, the Intel AMT
device remains awake until there is no activity for the number of
minutes set in the Idle Timeout. At that point the device reduces
power. Any network access to the Intel AMT device causes it to
wake up and restart the timeout timer.
If you want to use this parameter, set it to three minutes at a
minimum.
Idle timeout
Setup and configuration profile: Domains tab
The Domains tab defines the domains from which an Intel AMT computer can
initiate configuration by Intel SCS.
Click the Add symbol to add a domain.
If you want to allow configuration when the platform has no domain name, check
Allow configuration when platform has no domain name.
Domains tab: Add New Domain Entry dialog box
Use this dialog box to add a domain to the list of domains from which an AMT
computer can initiate configuration by Intel SCS.
Table 10-13
Options on the
Add New Domain Entry
dialog box
Description
Option
Type the name of the domain.
Domain name
About Out of Band Management Component pages
Configuration Profiles page
140
Содержание ALTIRIS OUT OF BAND MANAGEMENT COMPONENT 7.0 SP3 - V1.0
Страница 1: ...Altiris Out of Band Management Component from Symantec Implementation Guide Version 7 0 SP3 MR1 ...
Страница 6: ......
Страница 30: ...Introducing Out of Band Management Component Where to get more information 30 ...
Страница 48: ...Installing Out of Band Management Component Uninstalling Out of Band Management Component 48 ...
Страница 110: ...Configuring TLS Configuring TLS with mutual authentication 110 ...
Страница 176: ...Troubleshooting Out of Band Management Component Troubleshooting OOB site server installation 176 ...