ELECTRICS
68
•
Charging when the vehicle engine
is running
. When the vehicle engine is
running both the vehicle battery and the
leisure battery LED’s will flash in unison to
indicate that they are connected together
and are being charged by the vehicle.
•
Cabin Lights Button
. For motorhomes,
with the power on, press the cabin lights
button to turn the main lighting supply on
or off.
•
Awning Light Button
. For motorhomes,
with the power on, press the awning light
button to turn the awning light on or off.
•
Frost Protect Button
. For motorhomes if
/ when fitted, with the power on, press the
frost protect button to turn on the water
tank heating system. The adjacent LED
will illuminate to show that the tank heating
system is on.
2.7 Operation while driving
The EC400 system is designed to
shutdown parts of the system while the
engine is running. This is to meet Electro
Magnetic Compatibility (EMC) regulations
and to ensure the safe operation of the
caravan or motorhome. This is indicated
by the two battery LED’s flashing together.
Please ensure the system shutdown
switch on the PSU is in the “on” (button
in) position before driving (see 2.3). This
will ensure the electronic system is active
and will therefore be able to control the
charging process, supply the refrigerator
and monitor other system circuits.
On motorhomes if / when fitted,
designated 12v sockets, en-route reading
lights and en-route heating will remain
operational while the engine is running.
3 System Technical Information
The following section provides further
technical information relating to the
electrical system. You can also access the
supporting technical manual from www.
sargentltd.co.uk
3.1 Residual Current Device & Miniature
Circuit Breakers
Residual Current
Device (RCD)
Miniature Circuit
Breakers (MCB’s)
RCD
Test
button
The Residual Current Device (RCD) is
basically provided to protect the user
from lethal electric shock. The RCD will
turn off (trip) if the current flowing in the
live conductor does not fully return down
the neutral conductor, i.e. some current is
passing through a person down to earth or
through a faulty appliance.
To ensure the RCD is working correctly,
the test button should be operated each
time the vehicle is connected to the mains
supply (see section 2.4)
The Miniature Circuit Breakers (MCB’s)
operate in a similar way to traditional fuses
and are provided to protect the wiring
installation from overload or short circuit.
If an overload occurs the MCB will switch
off the supply. If this occurs you should
investigate the cause of the fault before
switching the MCB back on.
EC400 SERIES POWER SUPPLY SYSTEM
Содержание Motorhomes 2013
Страница 2: ...Motorhome Owner s Service and Warranty Handbook...
Страница 6: ...4...
Страница 16: ...WA RR A NT Y INF OR MATIO N 14...
Страница 17: ...MO TOR HOME CO DE 15 MOTORHOME CODE Code of conduct 16 The Country code 18 The Coastal code 18...
Страница 28: ...P RE PA RIN G F OR T H E R O A D 26...
Страница 32: ...E N R OU TE 30...
Страница 41: ...A RRIVA L AT SIT E 39 ARRIVAL AT SITE Positioning the motorhome 40...
Страница 52: ...SE R VICE S 50 GAS SCHEMATIC Typical gas schematic drawing with water heater...
Страница 53: ...SE RVICE S 51 GAS SCHEMATIC WITH COMBI BOILER Typical gas schematic drawing with Combi or Alde Boiler...
Страница 64: ...SE R VICE S 62...
Страница 167: ...F ITTE D E QU IP ME NT 165...
Страница 182: ...F IT T E D E QU IP M E N T 180 SHOWER COLOUR REFERENCE...
Страница 194: ...MA IN T E NA N CE 190...
Страница 200: ...U SE FU L INF OR MATIO N 196...
Страница 201: ...U SE F U L INF OR MAT ION 197...