FITTED EQUIPMENT
106
this area may be subject to elevated
temperatures.
Important operating notes
The integrity and tight fit of the exhaust gas
double duct must be checked regularly,
particularly at the end of long trips. Also check
the mounting of the appliance and the cowl.
Following a blow-back (misfire) always have
the exhaust gas system checked by an expert!
Always keep the cowl for the exhaust duct and
combustion air intake free of contamination
(slush, ice, leaves etc.).
The hot air outlets and the recirculated air
intake openings must be free so that the unit
does not overheat. The integrated temperature
limiter blocks the gas supply when the unit
becomes too hot.
Operating Instructions
Always observe the operating instructions and
“Important operating notes” prior to starting!
The vehicle owner is responsible for the
correct operation of the appliance.
Before using for the first time, it is essential to
flush the entire water supply system through
with clean water. If the heater is not being
used, always drain the water contents if there
is a risk of frost. There shall be no claims under
guarantee for damage caused by frost!
Taking into operation
Heating is possible without restrictions with
gas, electrical and mixed operation, with or
without water.
Check to make sure the cowl is unobstructed.
Be sure to remove any covers that may be
present.
For operating on gas turn on gas cylinder and
open the shut off valve at the manifold.
For operating on electric operate the heater
/ heating system heater switch on the power
supply unit. See page 65.
Summer operation (boiler operation only)
Mixed operation (gas and electrical) is not
possible in summer mode. With this setting the
unit automatically selects electrical operation
with a preselected power setting of 900 W or
1800 W.
Winter operation
·
Heating with water temperature
monitoring
The device automatically selects the
required power setting in accordance with
the temperature difference between the
temperature selected on the control panel
and the current room temperature. When the
room temperature selected on the control
panel is reached, the heater switches back to
the smallest setting and heats the water to 60
°C. Once the water temperature is reached,
the heater switches off and the yellow LED (p)
goes out. The warm air fan can continue to
run in order to cool the unit (after-run).
·
Heating without water temperature
monitoring
The device automatically selects the
required power setting in accordance with
the temperature difference between the
temperature selected on the control panel
and the current room temperature. Once the
room temperature selected on the control
panel has been reached, the heater switches
off. The warm air fan continues to run at slow
speed until the outgoing air temperature (on
the unit) has fallen to 40°C or less.
If the boiler is filled, the water will
automatically be heated at the same time.
The water temperature is then dependent
on the heating output being given off, and
the duration of heating required to reach the
desired room temperature.
· Heating with drained water system
Depending on the operating mode, the unit
will automatically select the required power
level according to the temperature difference
between the setting on the control panel
and the current room temperature. Once the
room temperature selected on the control
panel has been reached, the heater switches
off. The warm air fan continues to run at slow
TRUMA COMBI
Содержание Motorhomes 2013
Страница 2: ...Motorhome Owner s Service and Warranty Handbook...
Страница 6: ...4...
Страница 16: ...WA RR A NT Y INF OR MATIO N 14...
Страница 17: ...MO TOR HOME CO DE 15 MOTORHOME CODE Code of conduct 16 The Country code 18 The Coastal code 18...
Страница 28: ...P RE PA RIN G F OR T H E R O A D 26...
Страница 32: ...E N R OU TE 30...
Страница 41: ...A RRIVA L AT SIT E 39 ARRIVAL AT SITE Positioning the motorhome 40...
Страница 52: ...SE R VICE S 50 GAS SCHEMATIC Typical gas schematic drawing with water heater...
Страница 53: ...SE RVICE S 51 GAS SCHEMATIC WITH COMBI BOILER Typical gas schematic drawing with Combi or Alde Boiler...
Страница 64: ...SE R VICE S 62...
Страница 167: ...F ITTE D E QU IP ME NT 165...
Страница 182: ...F IT T E D E QU IP M E N T 180 SHOWER COLOUR REFERENCE...
Страница 194: ...MA IN T E NA N CE 190...
Страница 200: ...U SE FU L INF OR MATIO N 196...
Страница 201: ...U SE F U L INF OR MAT ION 197...