A-96.250.231 / 130421
AMI Turbitrack
Default Values
69
If Function = Control upw. or dnw:
Parameter: ......................................................................Meas. value
Settings: Actuator: ............................................................. Frequency
Settings: Pulse Frequency: ................................................ 120/min
Settings: Control Parameters: Setpoint:............................100 FNU
Settings: Control Parameters: P-band:.............................5.00 FNU
Settings: Control Parameters: Reset time:................................. 0 s
Settings: Control Parameters: Derivative Time: ......................... 0 s
Settings: Control Parameters: Control Timeout:..................... 0 min
Settings: Actuator:................................................. Time proportional
Cycle time: ............................................................................... 60 s
Response time: ....................................................................... 10 s
Settings: Actuator.......................................................... Motor valve
Run time: ................................................................................. 60 s
Neutral zone: .............................................................................5%
If Function = Timer:
Mode:.................................................................................... Interval
Interval:................................................................................... 1 min
Mode: ........................................................................................daily
Start time:.......................................................................... 00.00.00
Mode:.....................................................................................weekly
Calendar; Start time: ......................................................... 00.00.00
Calendar; Monday to Sunday:.................................................... Off
Run time: ................................................................................... 10 s
Delay:........................................................................................... 5 s
Signal output:............................................................................. cont
Output/Control: .......................................................................... cont
Input:
Active............................................................................when closed
Signal Outputs ........................................................................... hold
Output/Control .............................................................................. off
Fault..............................................................................................no
Delay.......................................................................................... 10 s
Miscellaneous
Language:............................................................................. English
Set default:....................................................................................no
Load firmware:..............................................................................no
Password:........................................................... for all modes 0000
Sample ID: ....................................................................... - - - - - - - -
Line break detection .....................................................................no