Graphical strobe controller
With the menu item strobe controller up to four strobes can be adjusted and displayed
graphically. The upper level is OPEN, lower level is CLOSED.
Strobe 0 is identical to the strobe adjusted in the camera window
•
The strobe is used in
o
Positive logic as standard
o
Negative logic, when “Inv” is selected
•
All times are related to the exposure time, which is shown on top and determines the
scale of the graphics.
•
Strobes controlling an illumination have to be within this time
•
Using the sliders the changes can be seen in the fields besides.