Serial command signals in RS232 or RS422 format which can be used to communicate
with or command external devices. See section 10.6 for more details.
5.3
Strobe
The strobe panel allows for accessing the following settings for controlling light
sources:
•
Strobe duration
•
Strobe delay (Start of strobe related to a trigger pulse)
•
Strobe polarity (positive/negative)
Within the camera settings dialog one strobe(STROBE0) can be set.
Here:
•
Start at 4950 µsec
•
Duration 534 µsec (Status ON)
•
Strobe polarity means
o
Positive ,Output = OPEN for Duration , CLOSED for the rest
o
Negative, Output = CLOSED for Duration