Also a strobe can be controlled, the total time sequence can be seen in the following drawing.
SeqInterval 0
SeqInterval 1
SeqInterval 2
ExpStart 0
ExpStop 0
ExpStart 1
ExpStop 1
StrobeStart 0
StrobeStop 0
PWM 100%
PWM 50%
StrobeStart and StobeStop determine the duration of the output signal
Within this time a pulse width modulation can control the intensity of an illumination, for
example
o
PWM100% = full time output
o
PWM50% = 50% output
For each sequence up to 4 PWM’s can be configured
These PWM’s are output data line and have to be directed to a physical output using
“Camera IO configuration” in “Camera” menu”. Otherwise there is no physical reaction in a
connected unit device.
Setup for physical PWM output is shown on the next page.
!! As told before the sequencer has its own trigger management. Software trigger is done with
SNAP. For hardware trigger IN0 to IN2 are selectable.