A multicast data stream can be identified in SVCapture by a change in a
camera view’s title. A multicast group (232.x.x.x) along with the used port will
be shown instead of a camera’s MAC that is usually displayed in that place.
Further the camera is operated as usual in the controlling application without
any changes to normal mode.
A listening application will see a hint “MULTICAST” in the “IP address” field of
the discovery dialog for a camera that is streaming in multicast mode along
with the IP address of the multicast group.
The “Multicast” group box will display the packet size that applies to the
running image data stream. The listening application has to have at least
that packet size available (jumbo frames) in order to properly connect
to the image data stream.
After selecting the multicast camera in the camera list of the discovery dialog
the OK button can be clicked or the camera entry can be double clicked in
order to connect to the already running image data stream.
Since the listening application does not have control access, all controls in the
‘SVCam Settings’ dialog will be disabled except the Close button.
Displaying live images
Connect a SVS-GigE-Camera with a network cable to your PC or network
switch.
Plug in the RJ 45 Camera connector and then plug in the AC/DC power supply.
Wait 15 seconds until the green LED at the RJ45 connector of the Camera
blinks sometimes. Then start “SVCapture.exe”.
After start of “SVCapture.exe”