![SVS-Vistek eco1050 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/svs-vistek/eco1050/eco1050_user-manual_1410867027.webp)
Users Manual – eco1050, eco2050, eco2150, eco4050, eco674, eco694, eco814
p. 27
The following input lines are available:
IN0
(only in HR family, not for eco family)
IN1
IN2
IN3
IN_RS232
The input lines can be connected to the following signal drains:
UART_IN
Trigger
any of the output lines
The dialog allows for assigning signal sources to all physical output lines and
for assigning physical inputs to logical input signals (signal drains).
When clicking on ‘Apply’ after making all adjustments then the new
assignments take effect. One has to click on ‘Save to EEPROM’ in order to
make them persistent. In case of any problems the ‘Factory defaults’ can be
restored by clicking on that button.
Source signals show current input.
Above SHOWING “eco 4 IO”. eco2 has 2 open drain outputs only.
6.1
Input Lines