o
Debouncer starts the “Trigger”
Trigger when IN1 or IN2 sends a signal, debounce signal one
o
IN1 goes to DEBOUNCER
o
DEBOUNCER goes to Logic A
o
IN2 goes to Logic B
o
LOLIC is used for Trigger
Either IN1 or IN2 triggers the camera, both have to be debounced
o
IN1 goes to LogicA
o
IN2 goes to LogicB
o
LOGIC goes to DEBOUNCER
DEBOUNCER goes to Trigger