5. Customize Settings
88
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
-
Only CARD
- set the device to require only card authorization
(
Always
,
Disable
, or custom schedule).
-
Private Auth
- set the device to allow a private authorization
method (
Disable
or
Enable
). If enabled, the authentication mode
of the user will be determined by a user’s “Private Auth Mode” set-
ting, which is located on the Details tab. If disabled, the authenti-
cation mode will be determined by operation mode settings of the
device.
-
Double Verification Mode
- set the device to require verification
from two users during a selected schedule (
Always
,
Disable
, or
custom schedule).
•
Mifare
-
Not use Mifare
- check this box to disable MIFARE card
authorization.
-
Use Template on Card
- check this box to use the template on
the MIFARE card for authorization.
-
View Mifare Layout
- click this button to configure the MIFARE
layout used by the device. For more information about configuring
MIFARE layouts, see section 3.5.3.6.
5.1.2.2 Fingerprint tab
The Fingerprint tab allows you to customize fingerprint
authorization settings for BioEntry Plus devices.
• Fingerprint
-
Security Level
- set the security level to use for fingerprint
authorization (
Normal
,
Secure
, or
Most Secure
). Keep in mind
that as the security level is increased, so too is the likelihood of a
false rejection.
-
Scan Timeout
- set the length of time before the fingerprint
scanner will timeout (
1 sec
to
20 sec
). If a user does not place a