5. Customize Settings
87
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
-
Wiegand [User]
- inserts the user ID of the authenticated user in
the ID field of the Wiegand string.
5.1.2 Customize Settings for BioEntry Plus Devices
The sections below describe the settings available for BioEntry Plus devices.
Customize the way BioEntry Plus devices function by changing these settings to
suit your particular environment and operational needs.
5.1.2.1 Operation Mode tab
The Operation Mode tab allows you to customize time and various
operation modes settings for BioEntry Plus devices.
• BioEntry Plus Time
-
Date
- manually set the device date with a drop-down calendar.
-
Time
- manually set the device time.
-
Sync with Host PC Time
- check this box to automatically
synchronize the device time with the time of the host computer.
-
Get Time
- get the current time displayed by the device.
-
Set Time
- set the time on the device.
•
Operation Mode Setting
- for each of the following options, click
the corresponding checkbox to enable Double Verification Mode,
which requires verification of two users’ credentials to gain entry to a
door.
-
All
- set the device to allow all types of authorization (
Always
,
Disable
, or custom schedule).
-
Card + Fingerprint
- set the device to require card plus finger-
print authorization (
Always
,
Disable
, or custom schedule).
-
Only Fingerprint
- set the device to require only fingerprint
authorization (
Always
,
Disable
, or custom schedule).