5. Customize Settings
82
Copyright © 2008, Suprema Inc. On the web: www.supremainc.com
-
Max Number of Entrance
- set the maximum number of entries
allowed during the specified time limit.
•
Default Group Setting
- select a default access group to be applied
to new users who have not been assigned to another access group.
5.1.1.5 Input tab
The input tab lists input settings you have specified for a BioStation
device. Buttons at the bottom of the tab allow you to add, modify, or
delete input settings. To add or modify settings, you must specify them
from the Input Setting window. For more information about configuring
input settings, see section 3.8.3.2.
•
Device
- select the BioStation (or Secure I/O) device for which you
will add or modify settings.
•
Port
- select an input port (
Input 0
,
Input 1
, or
Tamper
). For Secure
I/O devices, these settings are available:
Input 0
,
Input 1
,
Input 2
,
Input 3
.
•
Switch
- click the radio buttons to specify the normal position of the
input switch (
N/O - normally open
or
N/C - normally closed
).
•
Function
- select an action to associate with the input:
-
Not Use
- the input port will not be monitored.
-
Generic Input
- the input port will be monitored for a triggering
action (events specified with “Detect Input 0-3” in the Output
settings window—see section 5.1.1.6).
-
Emergency Open
- open doors controlled by this device. The
normal door open period will be ignored and doors will remain
open until an operator sends a “Close Door” command via the
Door/Zone Monitoring tab (see section 4.3.1).
-
Release All Alarms
- cancel alarms associated with this device.
-
Restart Device
- restart the device.